background image

C19 0 0 |

  C I R C U L A R C H A R T R ECO R D ER  |  C I/C 1 9 0 0/R EC- EN R E V. B

11

5  Fitting chart and pen capsules

75.0

dEG F

1

2

3

4

5

6

Al

A2

A3

A4

CH1

CH2

CH3

CH4

Raise pens

Lift the chart clamp and 

remove the chart (if fitted)

Fit the new chart 

ensuring that it is 

beneath the pen lifter 

bars

Locate the chart 

under the guides

Rotate the chart to align the 

time line with the red pen

Lower the chart clamp

Figure 8  Fitting the chart

75.0

dEG F

1

2

3

4

5

6

7

Al

A2

A3

A4

CH1

CH2

CH3

CH4

Raise pens

Gently pull the arm off the 

bracket – see 

Note

Remove spent 

capsule

Remove cap

Lifter bars

Ensure that the arm is 

located above its lifter 

bar

Fit new capsule 

ensuring that the arm 

locates in the pen 

capsule slot

Slide pen assembly 

onto the appropriate 

bracket until it clips 

into place – see 

Note

Figure 9  Fitting the pen capsules

Summary of Contents for Commander C1900

Page 1: ...ircular chart recorder DS C1900R EN Quick Reference Guide C1900 Circular chart recorder IM C1900 QR Operating Guide C1900 Circular chart recorder IM C1900 OGR Programming Guide C1900 Circular chart recorder IM C1900 PGR Installation Guide C1900 Circular chart recorder and recorder controller IM C1900 INS Operating Instructions C1900 Circular chart recorder and recorder controller IM C1900 MOD User...

Page 2: ...ion 4 3 Installation 5 Location 5 Mounting 6 4 Electrical connections 8 Accessing the terminal connections 8 Analog input type s selection 9 Channel connections 10 4 relay module connections 10 8 digital inputs or outputs connections 10 5 Fitting chart and pen capsules 11 6 Faceplate keys and displays 12 Front panel keys 12 Displays 12 7 Operator level menus 13 8 Configuration level menus 14 Basic...

Page 3: ...andards This product has been designed to satisfy the requirements of IEC61010 1 2010 3rd edition Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use and complies with US NEC 500 NIST and OSHA EC Directive 89 336 EEC Electrical In order to meet the requirements of the EC Directive 89 336 EEC for EMC regulations this product must be used in an industrial environm...

Page 4: ... 4X Dimensions Height 368 8 mm 15 23 in Width 382 mm 15 04 in Depth behind panel 141 5 mm 5 57 in Materials of construction Case Glass fiber filled polycarbonate Window Polycarbonate Weight Approx 6 6 kg 14 55 lb Electrical Power supply range 100 to 240 V AC 10 90 V min to 264 V AC max 50 60 Hz Power consumption 30 VA typical for full specification unit Inputs outputs Universal analog inputs Up to...

Page 5: ...ng electrical and magnetic fields If this is not possible particularly in applications where mobile communications equipment is expected to be used screened cables within flexible earthed metal conduit must be used Minimum At eye level location Avoid vibration Close to sensor Sensor Figure 1 General installation requirements 0 C 32 F min 55 C 131 F max 0 to 80 RH 0 to 95 RH Within humidity limits ...

Page 6: ... 0 11 06 376 3 14 81 1 2 3 4 Secure mounting brackets 4 to case Mark fixing centers on wall 4 Drill suitable holes 4 Secure instrument to wall using suitable fixings Figure 3 Wall mounting optional 1 2 3 4 Position mounting brackets to suit horizontal pipe mounting or vertical pipe mounting as required Secure mounting brackets to case using bolts and washers Secure using two nuts and washers Fit U...

Page 7: ... cut out dimensions Maximum cut out dimensions Mark 4 mounting holes Drill 4 suitable holes 4 holes 0 281 dia or tap for 1 4 in thread Notes 1 The instrument can be inserted into a panel cut out of any size between the minimum and maximum dimensions illustrated provided the cut out is positioned centrally relative to the fixing holes If the panel cut out is larger than the maximum a locally manufa...

Page 8: ...onforms to installation category II of IEC 61010 All connections to secondary circuits must have basic insulation After installation there must be no access to live parts for example terminals Terminals for external circuits are for use only with equipment with no accessible live parts If the indicator is used in a manner not specified by the company the protection provided by the equipment may be...

Page 9: ...R50 TR9 C110 R53 R44 2 3 L14 C122 L17 TRA9 C12 JC50 C104 IC6 C119 R64 C126 D15 IC5 C13 DJ4 IC19 TR6 STAR L11 mV THC 2 wire transmitter mA V RTD and resistance All other input types Figure 6 Input type selection main board INPUT OUTPUT MODUL E L5 R56 PL3 PL1 C33 C10 R27 R24 C38 C22 R21 IC20 C24 R30 C15 C25 R26 C1 9 R22 C27 C20 C14 R36 C35 R25 C30 C23 C21 C1 3 R44 C29 C26 C34 C17 C16 PL3 PL3 2 1 3 4...

Page 10: ... Common Normally closed Recommended diode Diode forward voltage 0 8 V 20 mA or use 2 1N4001 general purpose diodes in series Analog input see B to H Relay output Red White Red Link White Red 4 relay module connections 1 2 3 4 5 6 7 8 9 10 11 12 Normally closed Normally open Common Normally closed Normally open Common Normally closed Normally open Common Normally closed Normally open Common Relay 1...

Page 11: ...des Rotate the chart to align the time line with the red pen Lower the chart clamp Figure 8 Fitting the chart 75 0 dEG F 1 2 3 4 5 6 7 Al A2 A3 A4 CH1 CH2 CH3 CH4 Raise pens Gently pull the arm off the bracket see Note Remove spent capsule Remove cap Lifter bars Ensure that the arm is located above its lifter bar Fit new capsule ensuring that the arm locates in the pen capsule slot Slide pen assem...

Page 12: ...key Enables the operator to advance to the next menu page B Down scroll key Enables the operator to move between parameters in any page C Up Down keys Enables adjustment of any parameter value D Programmable soft key By default configured as home key but can be configured to perform other functions for example alarm acknowledge etc E Pen lift key Enables the operator to lift lower the pen s Displa...

Page 13: ... provides access to the configuration level To access the operator menus 1 From the operating page press the key to scroll through the available menu pages 2 Use the key to scroll through each page and its available parameters 3 Use the and keys to select the required parameters ACKNLG ALArMS Enables the operator to acknowledge any currently active alarms tOtALS PAGE Enables the operator to displa...

Page 14: ...To access the configuration level menus 1 From the normal operator view press the key until the OPrtOr LEVEL page is displayed 2 Use the and keys to scroll to the required menu 3 Press the key to scroll through the available settings bASIC CONFIG Enables the operator to configure all inputs and outputs alarms security passwords pens and chart settings AdVNCd CONFIG Enables the operator to configur...

Page 15: ...IG Basic Config Operator Level Select PV Pen Filter Scale Reset Offset Adjustment Cal Pen At 100 Cal Pen At 0 Span Adjust Scale Adjust SELECt ____ rESEt __ OFFSEt ____ SPAN ____ SEtPEN At 100 Scale Adjust SCALE AdJUSt SEtPEN At 0 Check Pen Cal CHECK __ _ Mains Filter FILtEr __ Hrt Set Up Digital Output Select Output SELECt ____ Output Source Digital Outputs dIGtAL OUtPtS SOUrCE ____ Polarity POLrt...

Page 16: ...ECt ECN __ EQN _ 1 EQN _ 7 SEt UP F KEYS F KEY 1 OPrtOr LEVEL bASIC CONFIG AdVNCd CONFIG Basic Config Advanced Config Operator Level Set Up Pen Functions Pen Functions Pen 1 Function PEN FUNCtN PEN 1 Pen 4 Function PEN 4 Function Key 2 F KEY 2 Function Key 3 F KEY 3 9 Security options Passwords are set and changed in the Access page in the Basic Configuration level Passwords can be set to secure a...

Page 17: ...in Set Up Totals page Code Error Action No error None 1 Main board Analog input and or analog output calibration is corrupt Power down and then up again If fault remains contact the local Service Organization 2 Module in position 2 3 Module in position 3 4 Module in position 4 5 Module in position 5 6 Module in position 6 Figure 10 Power up error codes The recorder also displays preprogrammed erro...

Page 18: ...18 C1900 CIRCUL AR CHART RECORDER CI C1900 REC EN REV B Notes ...

Page 19: ...C1900 CIRCUL AR CHART RECORDER CI C1900 REC EN REV B 19 Sales Service Software ...

Page 20: ...all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB ABB 2020 ABB Limited Measurement Analytics Howard Road St Neots Cambridgeshire PE19 8EU UK Tel 44 0 870 600 6122 Fax 44 0 1480 217 948 Email instrumentation gb abb...

Reviews: