Field and Software Tools
CalMaster2 and CheckMaster
3 Installation
IM/VCM2
Issue 6
9
3.2 MagMaster Connection
To enable a MagMaster system to be tested by the CalMaster2 it may be necessary to fit a small
adaptor board (see Section 3.2.1, page 10) to the MagMaster.
Once the adaptor is fitted to the MagMaster transmitter, the CalMaster2 can be connected easily to
the transmitter for testing at any time.
Extra adaptor kits are available (part no. WADX0089).
To enable a hard-wired MagMaster system to be tested by the CalMaster2 it may be necessary to fit
a small adaptor board (see Section 3.2.1, page 10) to the MagMaster.
To remove the MagMaster covers:
1.
Slide the cover down
A
.
2.
Pull out slightly and slide off
B
.
3.
Slacken the captive screws
C
.
4.
Remove the protective cover
D
.
Note.
The newer series VKH MagMaster does not need to have this adaptor board fitted as one
is already incorporated into its design.
Fig. 3.1 Removing the MagMaster Covers
A
B
C
D