ProduCT dEsCrIPTIon 

11

The electrical performance data on the rating plate is only valid if the motor is connected to a liquid 
cooling system. The requirements of the liquid cooling system are shown on a separate rating plate 
located on the motor, see Figure 1. An example of a separate rating plate can be seen in Figure 3.

Figure 3. 

Example of separate rating plate with liquid cooling system data.

2.2.  Expected lifetime

The expected lifetime is very dependent on the motor´s winding and bearing temperature. The lower the 
temperature the longer expected lifetime. The insulation system for the motor is class H, which means 
that the winding temperature should not exceed 180°C. If the winding temperature is kept below this 
limit, the expected lifetime of the insulation system is at least 20,000 hours. The electrical performance 
data on the rating plate, see Figure 2, is the continuous operation point (S1). Operating in this point will 
not compromise the expected lifetime. As a simplified method, the S1 power in a duty cycle can be 
calculated by the root mean square method:

    

Motors for heavy electrical vehicles, type AMXE132 

 

Product description

 

 

 

 

 

 

3BSY600011-BCM

 

12 (34)

 

 

 

 

 

The electrical performance data on the rating plate is only valid if the motor is connected to a 

cooling system. The requirements of the cooling system are shown on a separate rating plate 

located on the motor, see Figure 1. An example of a separate rating plate can be seen in Figure 3

 

 

Figure 3 

 

Example of separate rating plate with cooling system data 

2.2

 

Expected lifetime 

The expected lifetime is very dependent on the motor´s winding temperature. The lower the 

temperature the longer expected lifetime. The insulation system for the motor is class H, which 

means that the winding temperature should not exceed 180°C. If the winding temperature is kept 

below this limit, the expected lifetime of the insulation system is at least 25,000 hours. The 

electrical performance data on the rating plate, see Figure 2, is the continuous operation point (S1). 

Operating in this point will not compromise the expected lifetime. As a simplified method, the S1 

power in a duty cycle can be calculated by the root mean square method: 

𝑃𝑃𝑃𝑃

𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒

=

1

𝑇𝑇𝑇𝑇 �

�𝑀𝑀𝑀𝑀

𝑖𝑖𝑖𝑖

(

2

∗ 𝜋𝜋𝜋𝜋 ∗ 𝑛𝑛𝑛𝑛

60

)

𝑖𝑖𝑖𝑖

2

𝑇𝑇𝑇𝑇

𝑖𝑖𝑖𝑖=1

 

𝑛𝑛𝑛𝑛

=

𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠

 [

𝑟𝑟𝑟𝑟𝑠𝑠𝑠𝑠𝑟𝑟𝑟𝑟

]

 

𝑀𝑀𝑀𝑀

=

𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑟𝑟𝑟𝑟𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑠𝑠𝑠𝑠

 [

𝑁𝑁𝑁𝑁𝑟𝑟𝑟𝑟

]

 

𝑇𝑇𝑇𝑇

=

𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡

 

𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑡𝑡𝑡𝑡𝑠𝑠𝑠𝑠

 

𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑟𝑟𝑟𝑟𝑠𝑠𝑠𝑠

 

So, in a duty cycle, the rated torque and power on the rating plate could exceed the short term 

(peak torque and peak power) as long as the winding temperature do not exceed 180°C.  

As mentioned in the Product description, the motor is equipped with temperature sensors in the 

stator winding. In most inverters, it is possible to set a warning limit and a shutdown limit for the 

winding temperature. To not compromise the expected lifetime, the values in Table 2 are 

recommended. 

Action 

Limit 

Warning 

170°C 

Shut down 

180°C 

Table 2 

 

Recommended temperature limits 

The expected lifetime for bearings and external seals is not solely temperature dependent and 

needs to be evaluated based on the duty cycle. Please contact your local ABB sales office for 

technical support. 

 

n = speed [rpm]

M = torque [Nm]

T = total cycle time

So, in a duty cycle, the rated torque and power on the rating plate could be exceeded short term (peak 
torque and peak power) as long as the winding temperature do not exceed 180°C. 

As mentioned in the Product description, the motor is equipped with temperature sensors in the stator 
winding. In most inverters, it is possible to set a warning limit and a shutdown limit for the winding 
temperature. To not compromise the expected lifetime, the values in Table 1 are recommended.

Action

Limit

Warning

180°C

Shut down

200°C

Table 2. 

Recommended temperature limits.

NOTE:        The warning and shut down limits are only valid for short term operation. Prolonged 

operation at high stator winding temperatures will significantly impact the bearing grease 
lifetime.

The expected lifetime for bearings and external seals is not solely temperature dependent and needs to 
be evaluated based on the duty cycle. Please contact your local ABB sales office for technical support.

Summary of Contents for AMXE132

Page 1: ... MANUAL Motors for heavy electrical vehicles AMXE132 ...

Page 2: ...l incidental or consequential damages of any kind arising from the use of this document nor shall ABB be liable for incidental or consequential damages arising from the use of any software or hardware described in this document This document and parts thereof must not be reproduced or copied for use for other than that of the AMXE132 without ABB s written permission The contents thereof must not b...

Page 3: ...chanical installation 16 4 1 1 Preparation and lifting 16 4 1 2 Installation of coupling 16 4 1 3 Installation of motor in vehicle 17 4 2 Liquid cooling system installation 18 4 3 Electrical installation 19 4 3 1 High voltage connection 19 4 3 2 Low voltage connection 21 5 Operation 22 5 1 Failure mode operation 22 6 Inspection and maintenance 23 6 1 Safety Instructions 23 6 2 Inspection and Maint...

Page 4: ...f the motor 9 Figure 2 Example of rating plate 10 Figure 3 Example of separate rating plate with liquid cooling system data 11 Figure 4 The motor is delivered on a pallet 12 Figure 5 Position of lifting eye bolts 13 Figure 6 Lifting of motor 14 Figure 7 Geometrical tolerances for the mating coupling for B14 and B5 mounting 16 Figure 8 Max allowed height difference between D end and ND end 17 Figur...

Page 5: ...ve side of motor WARNING signal word used to indicate a potentially hazardous situation which if not avoided can result in death or serious injury Symbols used in this manual Caution risk of electric shock Safety Alert Symbol warns of a potential personal injury hazard Warning magnetic field Prohibition No access for people with active implanted cardiac devices pace maker Safety Alert Symbol warns...

Page 6: ...into consideration 1 3 Warranty The warranty period is 12 months after commissioning but no later than 18 months from the date of notification of being ready for shipment An extended warranty can be offered on request 1 4 Information on electromagnetic compatibility The user must take precautions during installation and operation in order not to impair the electromagnetic compatibility If it is ne...

Page 7: ...as cleaning agents and the use of lubricants can involve health and or safety hazards The recommended precautions and procedures stated by manufacturers should be followed Non authorized modifications as well as the use of tools components and auxiliary components not corresponding to the installation or maintenance instructions exclude any liability of the motor manufacturer The motor has rotatin...

Page 8: ...n the frame Special efforts have been made to decrease harmonic losses noise and torque pulsations The insulation system contains corona resistant materials has low water absorption properties and complies with temperature class H Standard features options are available 3 phase permanent magnet synchronous motor Inverter adapted design of active material Class H insulation system Temperature senso...

Page 9: ...on 1 External shaft seal 2 Flange end shield 3 Rating plate 4 LV Connector 5 HV Connector 6 Separate rating plate with liquid cooling system data 7 Side supports 8 NDE bearing 9 Shaft spline 10 DE bearing Figure 1 Exploded view of the motor ...

Page 10: ...default phase order Seen from D end 6 Type designation 7 Maximum ambient temperature 8 Temperature class of insulation system for the motor according to IEC60034 1 9 Degree of protection according to IEC60034 5 10 Serial number 11 Rated voltage 12 Connection 13 Rated frequency 14 Rated power 15 Rated speed 16 Rated current 17 Rated power factor 18 Defined duty according to IEC60034 1 19 Back EMF 2...

Page 11: ... 2 is the continuous operation point S1 Operating in this point will not compromise the expected lifetime As a simplified method the S1 power in a duty cycle can be calculated by the root mean square method 𝑃𝑃𝑃𝑃𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒 1 𝑇𝑇𝑇𝑇 𝑀𝑀𝑀𝑀𝑖𝑖𝑖𝑖 2 𝜋𝜋𝜋𝜋 𝑛𝑛𝑛𝑛 60 𝑖𝑖𝑖𝑖 2 𝑇𝑇𝑇𝑇 𝑖𝑖𝑖𝑖 1 𝑛𝑛𝑛𝑛 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 𝑟𝑟𝑟𝑟𝑠𝑠𝑠𝑠𝑟𝑟𝑟𝑟 𝑀𝑀𝑀𝑀 𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑟𝑟𝑟𝑟𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑠𝑠𝑠𝑠 𝑁𝑁𝑁𝑁𝑟𝑟𝑟𝑟 𝑇𝑇𝑇𝑇 𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡 𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡 𝑡...

Page 12: ...ree surface Figure 4 The motor is delivered on a pallet 3 1 2 Inspection of delivery Unpacking should be done carefully in order to avoid damage The delivery should be checked against the packing list NOTE When the motor arrives at its destination be sure to check the motor in order to determine possible transport damage as quickly as possible Any damage during delivery or deviations from the pack...

Page 13: ...ck that the lifting eye bolts are undamaged before lifting Damaged lifting eye bolts must be replaced before lifting Lifting must be performed with great care and using appropriate equipment When lifting the motor it is important to lift it in a way that does not affect any critical part such as the bearings shaft or connection box There are several holes at 3 6 and 9 o clock seen from the D end w...

Page 14: ...MOTORS FOR HEAVY ELECTRICAL VEHICLES 14 The angle between the lifting chains shall be a maximum of 60 see Figure 6 Figure 6 Lifting of motor ...

Page 15: ... that corrosion protection coating is removed for mating surfaces e g shaft and flange surfaces Tectyl 506 can be removed with Tectyl HPS solvent borne thinner vapor degreasing a hot alkaline wash or low pressure steam 3 4 Insulation resistance check Measure insulation resistance before commissioning after long periods of standstill or storage when winding dampness may be suspected Insulation resi...

Page 16: ...B5 mounting The values for X and Y depending on motor operating speed could be found in Table 3 Operating speed rpm Concentricity X Perpendicular Y Non flexible coupling Flexible coupling Non flexible coupling Flexible coupling 0 2000 0 13 0 25 0 001 0 002 2000 3000 0 10 0 20 0 0007 0 0015 3000 4000 0 07 0 15 0 0005 0 001 4000 5000 0 05 0 10 0 0002 0 0005 Table 3 Concentricity and perpendicular de...

Page 17: ...ent between the side support and the mating surfaces must be accurate The figure below illustrates the max allowed height difference between the D end and ND end To achieve this shims between the side support and the mating surfaces can be used ND end D end Max 0 1 Figure 8 Max allowed height difference between D end and ND end Recommended tightening torques can be seen in Table 4 Thread size Grad...

Page 18: ...d Figure 9 Position of liquid cooling inlet and outlet Recommended coolants are ethylene glycol based such as Antifrogen N from Clariant or propylene glycol based NOTE Coolants might be a toxic compound Use correct personal safety equipment and avoid exposure to the coolant Information about pressure drop as a function of flow rate and how glycol mixture affects performance is found in the motor d...

Page 19: ...Drive side of motor ND end or NDE Non drive side of motor WARNING signal word used to indicate a potentially hazardous situation which if not avoided can result in death or serious injury Symbols used in this manual Caution risk of electric shock Safety Alert Symbol warns of a potential personal injury hazard Warning magnetic field Prohibition No access for people with active implanted cardiac dev...

Page 20: ...Figure 11 Location of earth point and low voltage connector The earth cable from the inverter or vehicle chassis must be installed in an appropriate way and be suitable for high frequency currents NOTE Ensure that the dedicated surface on the earth point is free from paint and dirt to ensure a good connection ...

Page 21: ... standard configuration those will be empty A recommended mating low voltage connector can be seen in Figure 13 and Table 7 Figure 13 Recommended mating low voltage connector Type Comment Harting 19 40 703 0410 Housing Harting 09 12 021 3101 Female insert Harting 09 67 000 8476 Female crimp contact Harting 19 62 000 5080 M20 EMC cable gland Table 7 Recommended mating low voltage connector NOTE The...

Page 22: ... the winding ensure they are electrically connected to prevent possible condensation during standstill NOTE Operating in conditions below 20 C without proper options risks damaging critical mechanical components such as bearings internal and external seals etc 5 1 Failure mode operation Although not recommended the motor may operate for a short term in failure mode operation if this is unavoidable...

Page 23: ...Components Risk of burns caused by hot components Wait for hot components to cool down before starting the work Warning Magnetic field Prohibition No access for people with active implanted cardiac devices pacemaker Warning The liquid cooling system may be pressurized NOTE Only skilled and trained personnel should carry out maintenance When carrying out any work on electrical conductors the local ...

Page 24: ...wing areas 1 Listen for any abnormal noise or increased vibrations 2 Verify that the liquid cooling system connections for inlet and outlet are free from dust or any parts that block the flow If required clean the inlet and outlet areas Check that there are no fluid leakages The pressure drop may not exceed the rating on the separate rating plate see Figure 3 3 Verify that the temperature sensors ...

Page 25: ...endent on the motor s duty cycle and the external environment Check for wear and replace if necessary A damaged external shaft seal might compromise the IP class of the motor NOTE The external shaft seal should never run dry lubricate if necessary 6 3 5 Shaft spline Inspect the shaft splines see Figure 1 to ensure no excessive wear has occurred and apply a suitable molybdenum disulfide grease to t...

Page 26: ... the nozzle too close to the surface a minimum of 80 cm from the surface of the motor Caution must be taken during cleaning so that liquid is not forced inside the motor Do not direct the nozzle directly toward the following areas of the motor The external shaft seal Connection box and edges around connection box cover 6 3 7 Re painting The motor is painted with corrosion resistant paint color RAL...

Page 27: ...anty is only valid if recommended spare parts are used Spare parts and consumables must be stored in a vibration free dry moisture and dirt free storage The parts must be stored in a heated room where the temperature variations are small For information on price and delivery times please contact your local ABB sales office ...

Page 28: ...tential personal injury hazard Warning magnetic field Prohibition No access for people with active implanted cardiac devices pace maker Warning High Voltage Touching a live motor connection causes serious injuries or death The motor must be isolated from the power supply system prior to carrying out any investigations Mechanical failures Failure Possible cause of failure Corrective action Motor is...

Page 29: ...it is an electrical fault Motor current is abnormally high Fault in the stator winding Measure the winding resistance between the stator terminals Motor has different phase currents and gets high temperatures Asymmetrical feeding Check the similarity of the phase voltage on the incoming cables Motor gets an abnormally high phase current and high temperature also at no load Wrong incoming voltage l...

Page 30: ...ing In most countries the permanent magnets are not considered as hazardous waste and thus the motor can usually be disposed in the same manner as an induction motor Please check the local laws and regulation and contact your local ABB sales office for more information ...

Page 31: ...ng surfaces for side support mounting fulfilled Have all bolts been tightened with the correct tighten torque Has thread locking been applied to the bolts Has the spline been lubricated with a suitable molybdenum disulfide grease Liquid cooling system installation Are recommended mating cooling connectors used Is a recommended coolant used Are the requirements of the liquid cooling system accordin...