Standard function blocks
401
Switch & Demux
DEMUX-I
(10061)
Illustration
Execution time
1.38 µs (when two outputs are used) + 0.30 µs (for every additional output). When all
outputs are used, the execution time is 10.38 µs.
Operation
Input (I) value is stored to the output (OA1…OA32) selected by the address input (A).
All other outputs are 0.
If the address input is 0, negative or exceeds the number of the outputs, all outputs are
0.
Inputs
The input data type is selected by the user.
Address input (A): DINT
Input (I): INT, DINT, Boolean, REAL, REAL24
Outputs
The number of the output channels (1…32) is selected by the user.
Output (OA1…OA32): INT, DINT, REAL, REAL24, Boolean
DEMUX-MI
(10062)
Illustration
Execution time
0.99 µs (when two outputs are used) + 0.25 µs (for every additional output). When all
outputs are used, the execution time is 8.4 µs.
DEMUX-I
(BOOL)
81
TLA1 1 msec
(1)
A
I
OA1
OA1(81)
OA2
OA2(81)
DEMUX-MI
(BOOL)
82
TLA1 1 msec
(1)
A
R
L
S
I
OA1
OA1(82)
OA2
OA2(82)
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...