62.11
PRESET MODE
(see above)
Selects the preset mode.
Presets are used to set the position system to a parameter value (preset position) or actual position.
The physical position of the driven machinery is not changed, but the new position value is used as
home position.
Note:
Selections 1…3 can also be activated by the homing start command (source selected by
parameter
(0)
Disabled
Preset mode not in use.
(1)
Synch Ref
Synchron reference chain (parameter group
) is set to the value of
the preset position (
).
(2)
Act to Synch
Synchron reference chain (parameter group
) is set to the value of
the actual position (
).
(3)
Whole system
Position system (parameter groups
,
) is set to the
value of the preset position (
).
62.12
PRESET TRIG
(see above)
Selects the source for the preset mode start signal.
(0)
Homing start
The homing start signal (selected by parameter
) also activates the selected preset mode.
(1)
ENC1 DI1 _–
Rising edge of encoder 1 digital input DI1.
(2)
ENC1 DI1 –_
Falling edge of encoder 1 digital input DI1.
(3)
ENC1 DI2 _–
Rising edge of encoder 1 digital input DI2.
(4)
ENC1 DI2 –_
Falling edge of encoder 1 digital input DI2.
(5)
Reserved.
(6)
ENC1 Zerop
Rising edge of encoder 1 zero pulse.
(7)
ENC2 DI1 _–
Rising edge of encoder 2 digital input DI1.
(8)
ENC2 DI1 –_
Falling edge of encoder 2 digital input DI1.
(9)
ENC2 DI2 _–
Rising edge of encoder 2 digital input DI2.
(10)
ENC2 DI2 –_
Falling edge of encoder 2 digital input DI2.
(11)
Reserved.
(12)
ENC2 Zerop
Rising edge of encoder 2 zero pulse.
(13)
PROBE1 SW
Trigger probe 1 signal (selected by parameter
) also activates the selected preset mode.
(14)
PROBE2 SW
Trigger probe 2 signal (selected by parameter
) also activates the selected preset mode.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...