Parameters and firmware blocks
157
-8…8
Scaling factor for speed reference 1/2.
24.07
SPEEDREF NEG ENA
(see above)
Selects the source for the speed reference inversion. 1 = Sign of the speed reference is changed
(inversion active).
Bit pointer: Group, index and bit
24.08
CONST SPEED
(see above)
Defines the constant speed.
-30000…30000 rpm
Constant speed.
24.09
CONST SPEED ENA
(see above)
Selects the source for enabling the use of the constant speed reference define by parameter
. 1 = Enable.
Bit pointer: Group, index and bit
24.10
SPEED REF JOG1
(see above)
Defines the speed reference for jogging function 1. See section
on page
.
-30000…30000 rpm
Speed reference for jogging 1.
24.11
SPEED REF JOG2
(see above)
Defines the speed reference for jogging function 2. See section
on page
.
-30000…30000 rpm
Speed reference for jogging 2.
24.12
SPEED REFMIN ABS
(see above)
Defines the absolute minimum limit for the speed reference.
0…30000 rpm
Absolute minimum limit for speed reference.
Limited speed reference
Speed reference
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...