![ABB ACSM1 Series User Manual Download Page 25](http://html1.mh-extra.com/html/abb/acsm1-series/acsm1-series_user-manual_3352824025.webp)
Operation
25
How to change the value of value pointer parameters
In addition to the parameters shown above, there are two kinds of pointer
parameters; value pointer parameters and bit pointer parameters. The value pointer
parameter points to the value of another parameter/signal. The source parameter is
given in format
P.xx.yy
, where xx = Parameter group; yy = parameter index.
For more information, see appropriate
Firmware Manual
.
6.
• To save the new value, press
.
• To cancel the new value and keep the original, press
.
Step
Action
Display
1.
Go to the Main menu by pressing
if you are in the Output mode, otherwise
by pressing
repeatedly until you get to the Main menu.
2.
Go to the Parameters option by selecting PARAMETERS on the menu with
keys
and
, and pressing
.
3.
Select the appropriate parameter group with keys
and
. Here the
value pointer parameter 15.01 AO1 PTR is used as an example.
4.
Press
to select the appropriate parameter group. Select the appropriate
parameter with keys
and
, current value of each parameter is
shown below it.
5.
Press
. Current value of the value pointer parameter is shown, as well as
the parameter group it points to.
6.
Specify a new parameter group for the value pointer parameter to point to with
keys
and
. The parameter group changes respectively.
Step
Action
Display
SAVE
CANCEL
9901 LANGUAGE
9904 MOTOR TYPE
PMSM
9906 MOT NOM CURRENT
9907 MOT NOM VOLTAGE
PARAMETERS
EXIT
EDIT
00:00
LOC
MENU
EXIT
PARAMETERS
FAULT LOGGER
TIME & DATE
EXIT
ENTER
00:00
MAIN MENU
1
LOC
ENTER
01 ACTUAL VALUES
02 I/O VALUES
03 CONTROL VALUES
04 POS CTRL VALUES
06 DRIVE STATUS
EXIT
SEL
00:00
PAR GROUPS
01
LOC
10 START/STOP
11 START/STOP MODE
12 DIGITAL IO
13 ANALOGUE INPUTS
15 ANALOGUE OUTPUTS
EXIT
SEL
00:00
PAR GROUPS
15
LOC
SEL
1501 AO1 PTR
P.01.05
1502 AO1 FILT TIME
1503 AO1 MAX
1504 AO1 MIN
PARAMETERS
EXIT
EDIT
00:00
LOC
EDIT
1501 AO1 PTR
PAR EDIT
P.
01
.05
CANCEL
NEXT
00:00
01 ACTUAL VALUES
LOC
1501 Ao1 PTR
PAR EDIT
P.
02
.05
CANCEL
NEXT
00:00
02 I/O VALUES
LOC