background image

ACSM1

User’s Guide
ACSM1 Control Panel

Summary of Contents for ACSM1 Series

Page 1: ...ACSM1 User s Guide ACSM1 Control Panel...

Page 2: ...DriveSPC User Manual 3AFE68836590 English APPLICATION GUIDES Functional Safety Solutions with ACSM1 Drives Application Guide 3AUA0000031517 English Safe Torque Off Function STO Application Guide 3AFE6...

Page 3: ...ACSM1 Control Panel User s Guide 3AUA0000020131 Rev B EN EFFECTIVE 2009 08 12 2009 ABB Oy All Rights Reserved...

Page 4: ......

Page 5: ...el 10 Features 10 Overview 10 Maintenance 10 Status line 11 Installation What this chapter contains 13 Connecting the panel to the drive 13 The cable 13 Mounting the control panel 14 Mounting template...

Page 6: ...int to the value of a bit in another signal 27 How to change the value of bit pointer parameter to fixed 0 FALSE or 1 TRUE 29 Fault Logger 31 How to view faults 31 How to reset faults 31 Time Date 32...

Page 7: ...ging the default settings of the function For warnings and notes see appropriate Firmware Manual Intended audience This manual is intended for persons who install and use the panel Product and service...

Page 8: ...About the manual 8...

Page 9: ...sing the panel in control monitoring and changing the settings About control panels Use a control panel to control the ACSM1 read status data and adjust parameters Compatibility The manual is compatib...

Page 10: ...ction depends on the context The text in the lower left corner of the LCD display indicates the function 4 Soft key 2 Function depends on the context The text in the lower right corner of the LCD disp...

Page 11: ...Drive is running at reference point Dotted rotating arrow Drive is running but not at reference point Stationary arrow Drive is stopped Dotted stationary arrow Start command is present but the motor i...

Page 12: ...Hardware description 12...

Page 13: ...he drive The control panel connection to the drive is shown in the figure below See also ACSM1 04 Drive Modules Hardware Manual 3AFE68797543 English The cable CAT5 straight through network cable max 3...

Page 14: ...nel mounting kits IP21 68294673 and IP66 68829593 The kits contain an extension cable a gasket and other mounting accessories needed for installing the panel to the cabinet door The kits also contain...

Page 15: ...Installation 15 Mounting template...

Page 16: ...Installation 16 Gasket...

Page 17: ...lighted and then pressing the relevant soft key With the right soft key you usually enter a mode accept an option or save the changes The left soft key is used to cancel the made changes and return to...

Page 18: ...mode Output 23 How to adjust the display contrast Output 23 How to change the value of a parameter Parameters PARAMETERS 24 How to change the value of value pointer parameters Parameters PARAMETERS 2...

Page 19: ...r the drive 2 Keep key pressed down while you switch on the power and read the information The display shows the following panel information Panel SW panel firmware version ROM CRC panel ROM check sum...

Page 20: ...To switch to local control LOC and control the drive using the control panel press The result depends on how long you press the key If you release the key immediately the display flashes Switching to...

Page 21: ...signal values or bar graphs How to change the direction of the motor rotation Step Action Display 1 If you are not in the Output mode press repeatedly until you get there 2 If the drive is in remote...

Page 22: ...the Output mode and how they are displayed with group 17 PANEL DISPLAY parameters See page 24 for detailed instructions on changing parameter values 1701 SIGNAL1 PARAM PAR EDIT 01 03 CANCEL NEXT 00 00...

Page 23: ...nce value shown in the top right corner of the display press The value changes immediately It is stored in the permanent memory of the drive and restored automatically after power switch off To decrea...

Page 24: ...r the parameter with keys and Pressing the key once increments or decrements the value Holding the key down changes the value faster Pressing the keys simultaneously replaces the displayed value with...

Page 25: ...to select the appropriate parameter group Select the appropriate parameter with keys and current value of each parameter is shown below it 5 Press Current value of the value pointer parameter is show...

Page 26: ...r changes respectively 8 To save the new value for the pointer parameter press To cancel the new value and keep the original press The new value is shown in the parameters list Step Action Display NEX...

Page 27: ...t mode otherwise by pressing repeatedly until you get to the Main menu 2 Go to the Parameters option by selecting PARAMETERS on the menu with keys and and pressing 3 Select the appropriate parameter g...

Page 28: ...it number and name if defined change respectively Here bit 00 stands for bit number 20 1 the first bit from the right in a 32 bit signal 10 To save the new value for the bit pointer parameter press To...

Page 29: ...select the appropriate parameter group Select the appropriate parameter with keys and Current value of each parameter is shown below its name 5 Press Select CONST with keys and 6 Press 7 Specify a ne...

Page 30: ...o cancel the new value and keep the original press The new value is shown in the parameters list Step Action Display SAVE CANCEL 1201 DI01 CONF9901 1202 DI02 CONF 1203 DI03 CONF 1204 DI01 OUT PTR C TR...

Page 31: ...e fault log starting with the most recent fault The number on the row is the fault code according to which the causes and corrective actions are listed in appropriate Firmware Manual To see the detail...

Page 32: ...CLOCK VISIBILITY on the menu press select Show clock Hide clock with keys and and press or if you want to return to the previous display without making changes press To specify the time format select...

Page 33: ...ght saving time is used in each country or area whose daylight saving changes you can select to be followed Scroll the text with keys and To return to the previous display press To disable automatic c...

Page 34: ...the control panel with SHOW BACKUP INFO This includes e g version information etc of the current backup file in the panel It is useful to check this information when you are going to restore the param...

Page 35: ...the Par Backup with keys and Press Restoring starts Backup interface version is checked Scroll the text with keys and If you want to continue press Press if you want to stop the operation If the down...

Page 36: ...y pressing 3 The panel shows details about the version check For details of the information fields shown on the control panel see section How to view information about the backup on page 41 You can sc...

Page 37: ...ows a message about it Downloading continues drive is being restarted The display shows the transfer status as a percentage of completion Downloading continues Downloading finishes Initializing param...

Page 38: ...me Press when you have edited parameters Step Action Display 1 Restore operation starts normally 2 Version check is also OK You can see on the panel that the firmware versions are not the same You can...

Page 39: ...is being restarted 8 Downloading finishes 9 Panel shows a text identifying the alarm and returns to the Par Backup Step Action Display Initializing param restore operation PAR BACKUP LOC 00 00 Restar...

Page 40: ...he parameter group 16 Select parameter 16 09 USER SET SEL with keys and Current value of each parameter is shown below its name 3 Press Select the user set you want to load with keys and Press 4 Panel...

Page 41: ...firmware UMFI Firmware of the ACSM1 drive 1330 Firmware version e g 1 330 0 Firmware patch version PRODUCT VARIANT 1 ACSM1 Speed 2 ACSM1 Motion You can scroll the information with keys and 4 Press to...

Page 42: ...the Output mode otherwise by pressing repeatedly until you get to the Main menu 3 Go to the Reference Edit option by selecting REF EDIT on the menu with keys and and pressing 4 Select the correct sig...

Page 43: ...n DriveStudio commissioning and maintenance tool DRIVE TYPE Product variant e g ACSM1 Speed or ACSM1 Motion DRIVE MODEL Type code of the drive FW VERSION See page 41 SOLUTION PROGRAM Information on th...

Page 44: ...Operation 44...

Page 45: ......

Page 46: ...3AUA0000020131 Rev B EN EFFECTIVE 2009 08 12 ABB Oy AC Drives P O Box 184 FI 00381 HELSINKI FINLAND Telephone 358 10 22 11 Fax 358 10 22 22681 Internet www abb com...