428 Parameters
(Visible when user lock is open)
Confirms the new user pass code entered in
10000000…
99999999
Confirmation of new user pass code.
-
(Visible when user lock is open)
Selects the actions or functionalities to be prevented by the
user lock. Note that the changes made take effect only when
the user lock is closed. See parameter
.
Note:
We recommend you select all the actions and
functionalities unless otherwise required by the application.
1000b
0000h…FFFFh
Selection of actions to be prevented by user lock.
-
(Only visible when IGBT supply unit control activated by
)
Changing the value of this parameter to 1 reboots the supply
control unit (without requiring a power off/on cycle of the drive
system).
The value reverts to 0 automatically.
0
0…1
1 = Reboot the supply control unit.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Information
0
Disable ABB access
levels
1 = ABB access levels (service, advanced programmer, etc.; see
) disabled
1
Freeze parameter
lock state
1 = Changing the parameter lock state prevented, ie. pass code
358 has no effect
2
Disable file
download
1 = Loading of files to drive prevented. This applies to
• firmware upgrades
• safety functions module (
) configuration
• parameter restore
• loading an adaptive program
• loading and debugging an application program
• changing home view of control panel
• editing drive texts
• editing the favorite parameters list on control panel
• configuration settings made through control panel such as
time/date formats and enabling/disabling clock display.
3
Disable FB write to
hidden
1 = Access to parameters on disabled access levels from fieldbus
prevented.
4…5
Reserved
6
Protect AP
1 = Creating a backup and restoring from a backup prevented.
7
Disable panel
Bluetooth
1 = Bluetooth disabled on ACS-AP-W control panel. If the drive is
part of a panel bus, Bluetooth is disabled on all panels.
8…10
Reserved
11
Disable OEM access
level 1
1 = OEM access level 1 disabled
12
Disable OEM access
level 2
1 = OEM access level 2 disabled
13
Disable OEM access
level 3
1 = OEM access level 3 disabled
14…15 Reserved
Summary of Contents for ACS880-x04
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Page 4: ......
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 112: ...112 Application macros ...
Page 496: ...496 Additional parameter data ...
Page 544: ...544 Fault tracing ...
Page 602: ...602 Control chain diagrams ...