160 Parameters
ACS800-compatible fault word 2.
The bit assignments of this word correspond to FAULT
WORD 2 in the ACS800. Parameter
determines whether the bit assignments
are according to the ACS800 Standard or ACS800 System
control program.
Each bit can indicate several ACS880 events as listed below.
This parameter is read-only.
-
0000h…FFFFh
ACS800-compatible fault word 2.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
ACS800 fault name
ACS880 events indicated by this bit
, page
)
(
)
(
0
SUPPLY PHASE
SUPPLY PHASE
1
NO MOT DATA
NO MOTOR DATA -
2
DC UNDERVOLT
DC UNDERVOLT
3
Reserved
CABLE TEMP
4
RUN ENABLE
RUN DISABLE
5
ENCODER ERR
ENCODER ERR
,
,
6
I/O COMM
IO COMM ERR
7
CTRL B TEMP
CTRL B TEMP
-
8
EXTERNAL FLT
SELECTABLE
9
OVER SWFREQ
OVER SWFREQ
-
10
AI < MIN FUNC
AI<MIN FUNC
11
PPCC LINK
PPCC LINK
,
12
COMM MODULE
COMM MODULE
,
13
PANEL LOSS
PANEL LOSS
14
MOTOR STALL
MOTOR STALL
15
MOTOR PHASE
MOTOR PHASE
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...