![ABB ACS880-01 Series Firmware Instructions Download Page 164](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621164.webp)
164 Parameters
ACS800 System
ctrl program
The bit assignments of parameters
…
correspond
to the ACS800 System control program as follows:
: 09.01 FAULT WORD 1
: 09.02 FAULT WORD 2
: 09.04 ALARM WORD 1
: 09.05 ALARM WORD 2
1
05
Various run-time-type counters and measurements related to
drive maintenance.
All parameters in this group are read-only unless otherwise
noted.
On-time counter. The counter runs when the drive is
powered.
-
0…65535 d
On-time counter.
1 = 1 d
Motor run-time counter. The counter runs when the inverter
modulates.
-
0…65535 d
Motor run-time counter.
1 = 1 d
Running time of the drive cooling fan. Can be reset from the
control panel by keeping Reset depressed for over 3
seconds.
-
0…65535 d
Cooling fan run-time counter.
1 = 1 d
Estimated drive temperature in percent of fault limit. The
actual trip temperature varies according to the type of the
drive.
0.0% = 0 °C (32 °F)
94% approx. = Warning limit
100.0% = Fault limit
-
-40.0 … 160.0%
Drive temperature in percent.
1 = 1%
Diagnostic word 3.
-
0000h…FFFFh
Diagnostic word 3.
1 = 1
Displays the age of the main cooling fan as a percentage of
its estimated lifetime. The estimate is based on the duty,
operating conditions and other operating parameters of the
fan. When the counter reaches 100%, a warning (
) is generated.
Can be reset from the control panel by keeping Reset
depressed for over 3 seconds.
-
0…150%
Main cooling fan age.
1 = 1%
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Value
0…10
Reserved
11
Fan command
1 = Drive fan is rotating above idle speed
12
Fan service
counter
1 = Drive fan service counter has reached its limit
13…15 Reserved
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...