
Fault tracing
11
A8B0
ABB Signal
supervision 1
(Editable message text)
Programmable warning:
32.06
Supervision 1 action
Warning generated by the
signal supervision function 1.
Check the source of the warning
(parameter
32.07
Supervision 1 signal
).
A8B1
ABB Signal
supervision 2
(Editable message text)
Programmable warning:
32.16
Supervision 2 action
Warning generated by the
signal supervision function 2.
Check the source of the warning
(parameter
32.17
Supervision 2 signal
).
A8B2
ABB Signal
supervision 3
(Editable message text)
Programmable warning:
32.26
Supervision 3 action
Warning generated by the
signal supervision function 3.
Check the source of the warning
(parameter
32.27
Supervision 3 signal
).
A8B3
ABB Signal
supervision 4
(Editable message text)
Programmable warning:
32.36
Supervision 4 action
Warning generated by the
signal supervision function 4.
Check the source of the warning
(parameter
32.37
Supervision 4 signal
).
A8B4
ABB Signal
supervision 5
(Editable message text)
Programmable warning:
32.46
Supervision 5 action
Warning generated by the
signal supervision function 5.
Check the source of the warning
(parameter
32.47
Supervision 5 signal
).
A8B5
ABB Signal
supervision 6
(Editable message text)
Programmable warning:
32.56
Supervision 6 action
Warning generated by the
signal supervision function 6.
Check the source of the warning
(parameter
32.57
Supervision 6 signal
).
A8BE ULC overload warning
Programmable fault:
37.03
ULC overload
actions
Selected signal has exceeded
the user overload curve.
Check for any operating conditions
increasing the monitored signal (for
example, the loading of the motor if the
torque or current is being monitored).
Check the definition of the load curve
(parameter group
37 User load curve
).
A8BF
ULC underload
warning
Programmable fault:
37.04
ULC underload
actions
Selected signal has fallen
below the user underload
curve.
Check for any operating conditions
decreasing the monitored signal (for
example, loss of load if the torque or
current is being monitored).
Check the definition of the load curve
(parameter group
37 User load curve
).
A981
External warning 1
(Editable message text)
Programmable warning:
31.01
External event 1
source
31.02
External event 1
type
Fault in external device 1.
Check the external device.
Check setting of parameter
31.01
External event 1 source
.
A982
External warning 2
(Editable message text)
Programmable warning:
31.03
External event 2
source
31.04
External event 2
type
Fault in external device 2.
Check the external device.
Check setting of parameter
31.03
External event 2 source
.
Code
(hex)
Warning / Aux. code
Cause
What to do