Actual signals and parameters 299
NOT SEL
No reset signal
0
DI1
Reset through digital input DI1. 1 = active, 0 = inactive.
1
DI2
See selection
.
2
DI3
See selection
.
3
DI4
See selection
.
4
DI5
See selection
.
5
STATE 1
Reset during state transition to state 1. Counter is reset,
when the state has been reached.
6
STATE 2
Reset during state transition to state 2. Counter is reset,
when the state has been reached.
7
STATE 3
Reset during state transition to state 3. Counter is reset,
when the state has been reached.
8
STATE 4
Reset during state transition to state 4. Counter is reset,
when the state has been reached.
9
STATE 5
Reset during state transition to state 5. Counter is reset,
when the state has been reached.
10
STATE 6
Reset during state transition to state 6. Counter is reset,
when the state has been reached.
11
STATE 7
Reset during state transition to state 7. Counter is reset,
when the state has been reached.
12
STATE 8
Reset during state transition to state 8. Counter is reset,
when the state has been reached.
13
SEQ PROG
RST
Reset signal source defined by parameter
14
8420 ST1 REF SEL
Selects the source for the Sequence programming state 1
reference. Parameter is used when parameter
is set to
.
Note:
Constant speeds in group
overwrite the selected Sequence programming reference.
0.0%
COMM
. For scaling, see
on page
-1.3
AI1/AI2
Reference is calculated with the following equation:
REF = AI1(%) · (50% / AI2 (%))
-1.2
AI1-AI2
Reference is calculated with the following equation:
REF = AI1(%) + 50% - AI2(%)
-1.1
AI1*AI2
Reference is calculated with the following equation:
REF = AI1(%) · (AI2(%) / 50%)
-1.0
AI1+AI2
Reference is calculated with the following equation:
REF = AI1(%) + AI2(%) - 50%
-0.9
All parameters
No.
Name/Value
Description
Def/FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...