Actual signals and parameters 295
8403 SEQ PROG
PAUSE
Selects the source for the Sequence programming pause
signal. When Sequence programming pause is activated, all
timers and outputs (RO/TO/AO) are frozen. Sequence
programming state transition is possible only by parameter
DI1(INV)
Pause signal through inverted digital input DI1. 0 = active, 1
= inactive.
-1
DI2(INV)
See selection
.
-2
DI3(INV)
See selection
.
-3
DI4(INV)
See selection
.
-4
DI5(INV)
See selection
.
-5
NOT SEL
No pause signal
0
DI1
Pause signal through digital input DI1. 1 = active, 0 =
inactive.
1
DI2
See selection
.
2
DI3
See selection
.
3
DI4
See selection
.
4
DI5
See selection
.
5
PAUSED
Sequence programming pause enabled
6
8404 SEQ PROG
RESET
Selects the source for the Sequence programming reset
signal. Sequence programming state (
) is set to the first state and all timers and outputs
(RO/TO/AO) are set to zero.
Reset is possible only when Sequence programming is
stopped.
DI1(INV)
Reset through inverted digital input DI1. 0 = active, 1 =
inactive.
-1
DI2(INV)
See selection
.
-2
DI3(INV)
See selection
.
-3
DI4(INV)
See selection
.
-4
DI5(INV)
See selection
.
-5
NOT SEL
No reset signal
0
DI1
Reset through digital input DI1. 1 = active, 0 = inactive.
1
DI2
See selection
.
2
DI3
See selection
.
3
DI4
See selection
.
4
DI5
See selection
.
5
RESET
Reset. After reset parameter value is automatically set to
6
All parameters
No.
Name/Value
Description
Def/FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...