Actual signals and parameters in ACS800 Standard Application Program
36
83.03 EDIT BLOCK
Defines the block location number for the command selected by parameter
1 … 15
Block location number.
83.04 TIMELEVEL SEL
Selects the execution cycle time for the Adaptive Program. The setting is
valid for all blocks.
12 ms
12 milliseconds
100 ms
100 milliseconds
1000 ms
1000 milliseconds
84
ADAPTIVE PROGRAM Creation and diagnostics of the Adaptive Program.
84.01 STATUS
Shows the value of the Adaptive Program status word. The table below
shows the alternative bit states and the corresponding values on the panel
display.
84.02 FAULTED PAR
Points out the faulted parameter in the Adaptive Program.
84.05 BLOCK1
Selects the function block for Block Parameter Set 1.
ABS
See the chapter
ADD
See the chapter
AND
See the chapter
COMPARE
See the chapter
EVENT
See the chapter
FILTER
See the chapter
MAX
See the chapter
MIN
See the chapter
MULDIV
See the chapter
NO
See the chapter
OR
See the chapter
PI
See the chapter
PI-BAL
See the chapter
SR
See the chapter
SWITCH-B
See the chapter
SWITCH-I
See the chapter
TOFF
See the chapter
TON
See the chapter
TRIGG
See the chapter
XOR
See the chapter
Index Parameter name /
value
Description
FbEq
Bit Display Meaning
0
1
Stopped
1
2
Running
2
4
Faulted
3
8
Editing
4
10
Checking
5
20
Pushing
6
40
Popping
8
100
Initialising