Appendix A – ACS/ACC/ACP 601 Technical Data
ACS/ACC/ACP 601 Drives
ACx=ACS/ACC/ACP
A-13
Ambient Conditions
ACx 600 AC drives are to be used in a heated, indoor controlled
environment as specified below.
1)
At sites over 1000 m (3300 ft) above sea level, the maximum output current is
derated 1 % for every additional 100 m (330 ft). If the installation site is higher than
2000 m (6600 ft) above sea level, please contact your local ABB distributor or office for
further information.
2)
See subsection
Output Current Temperature Derating
, page A-3.
ACS/ACC/ACP 600
Operation
installed for stationary use
Storage
in the protective package
Transportation
in the protective package
Installation Site
Altitude
Nominal output power at 0 to
1000 m (3300’) above sea
level.
1)
-
-
Air Temperature
0 to +40 °C (32 to 104 °F)
2)
(IP 21/22 and ACx 607 with IP
54)
0 to +25 °C (32 to 77 °F)
2)
(ACx 601 with IP 54)
-40 to +70 °C
-40 to +158 °F
-40 to +70 °C
-40 to +158 °F
Relative Humidity
5 to 95 %
Max. 95 %
Max. 95 %
No condensation allowed. Maximum allowed relative humidity is 60 % in the presence of
corrosive gases.
Contamination
Levels
(IEC 721-3-3)
No conductive dust allowed.
Boards without coating:
Chemical gases: Class 3C2
Solid particles: Class 3S2
Boards with coating:
Chemical gases: Class 3C3
Solid particles: Class 3S2
Boards without coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
Boards with coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
Boards without coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
Boards with coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
Atmospheric
Pressure
70 to 106 kPa
0.7 to 1.05 atmospheres
70 to 106 kPa
0.7 to 1.05 atmospheres
60 to 106 kPa
0.6 to 1.05 atmospheres
Vibration
(IEC 68-2-6)
Max. 0.3 mm (0.01 in) (2 to 9
Hz), max. 1 m/s
2
(3.3 ft/s
2
)(9 to
200 Hz) sinusoidal
Max. 1.5 mm (0.06 in) (2 to 9
Hz), max. 5 m/s
2
(16.4 ft/s
2
)
(9 to 200 Hz) sinusoidal
Max. 3.5 mm (0.14 in) (2 to 9
Hz), max. 15 m/s
2
49.2 ft/s
2
)
(9 to 200 Hz) sinusoidal
Shock
(IEC 68-2-29)
Not allowed
Max. 100 m/s
2
, 11 ms
(330 ft/s
2
)
Max. 100 m/s
2
, 11 ms
(330 ft/s
2
)
Free Fall
Not allowed
250 mm (10in) (weight under
100 kg) (220 lbs)
100 mm (4 in)(weight over 100
kg) (220 lbs)
250 mm (10in) (weight under
100 kg) (220 lbs)
100 mm (4 in)(weight over 100
kg) (220 lbs)
Summary of Contents for ACS 601
Page 4: ......
Page 6: ......
Page 14: ...Safety Instructions x ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 18: ...xiv ACx ACS ACC ACP ACS ACC ACP Drives ...
Page 22: ...Chapter 1 Introduction 1 4 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 26: ...Chapter 2 Mechanical Installation 2 4 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 40: ...Chapter 3 Electrical Installation 3 14 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 42: ...Chapter 4 Installation Checklist 4 2 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 44: ...Chapter 5 Maintenance 5 2 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 82: ...Appendix B ACS ACC ACP 601 Dimensional Drawings B 14 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Page 87: ......