background image

Table of contents

4

Summary of Contents for ACS 600 MultiDrive

Page 1: ...ACS600 ACS800 Installation Guide du dt Filters AOCH0260 70 AOCH0400 70 NOCH0016 6x NOCH0030 6x NOCH0070 6x NOCH0120 6x NOCH0260 60 NOCH0400 60 NOCH0760 60...

Page 2: ...3AFE 58933368 REV D EN EFFECTIVE 20 10 2003 2003 ABB Oy All Rights Reserved...

Page 3: ...tallation Guide Contents 5 General notes and restrictions 5 Technical data 7 Ambient conditions operation 7 Ambient conditions storage 7 Ambient conditions transportation 8 Internal circuit diagrams 9...

Page 4: ...Table of contents 4...

Page 5: ...erter the motor or the motor cable It is good practice to check with a voltage indicating instrument that the drive is in fact discharged before beginning work Unprotected IP00 filters must be encased...

Page 6: ...p of each other with SingleDrive types 0320 5 0610 5 and 0610 7 the filters need a minimum of 700 m3 h of forced cooling Maximum of three filters can be mounted on top of each other NOCH0016 60 62 NOC...

Page 7: ...s operation Ambient operating conditions refer to the conditions du dt filters are subjected to when installed for stationary use Air temperature 15 to 50 C At temperatures from 40 C to 50 C the rated...

Page 8: ...60068 2 NOCH0xxx 6x Max 0 3 mm 2 to 9 Hz max 1 m s2 9 to 200 Hz sinusoidal IEC 60068 2 Shock Max 100 m s2 11 ms IEC 60068 2 27 Ambient conditions transportation Ambient transportation conditions refer...

Page 9: ...ms 1 A 2 X 1 1 1 2 2 1 2 2 AOCH0xxx 70 Connect the input terminals together output input NOCH0120 60 1 A 2 X NOCH0260 60 NOCH0400 60 NOCH0760 60 1 1 1 2 2 1 2 2 1 A 2 X U1 V1 W1 U2 V2 W2 PE NOCH0016 6...

Page 10: ...du dt Filters Installation Guide 10 Power connections NOCH0260 60 NOCH0400 60 NOCH0760 60 NOCH0400 60...

Page 11: ...du dt Filters Installation Guide 11 NOCH0016 6x NOCH0030 6x NOCH0070 6x NOCH0120 6x NOCH0260 60 NOCH0400 60 NOCH0760 60 AOCH0260 70 AOCH0400 70...

Page 12: ...du dt Filters Installation Guide 12 NOCH0760 60...

Page 13: ...du dt Filters Installation Guide 13 NOCH0400 60...

Page 14: ...du dt Filters Installation Guide 14 NOCH0400 60...

Page 15: ...du dt Filters Installation Guide 15 AOCH0400 70 AOCH0260 70...

Page 16: ...s with insulating tape or shrink tubing PE NOCH0120 6x Cable lug installation 16 to 70 mm2 6 to 2 0 AWG cables NOCH0120 6x Cable terminal installation 95 to 185 mm2 3 0 AWG to 350 MCM cables a Connect...

Page 17: ...0260 6 1 0260 3 0320 3 0320 5 0400 5 0320 6 0400 6 1 0400 3 0490 5 0490 6 2 0490 3 0610 3 0610 5 0760 5 0610 6 0760 6 2 0900 6 1 0760 3 0930 3 0930 5 1090 5 1040 6 1380 6 3 1120 3 1380 5 1710 6 2 144...

Page 18: ...60 6 0070 6 1 0070 3 0100 3 0120 3 0100 5 0120 5 0140 5 0100 6 0120 6 1 0185 3 0225 3 0215 5 0255 5 0185 6 0205 6 0255 6 0315 6 1 0265 3 0335 3 0325 5 0395 5 0375 6 0485 6 1 0405 3 0500 3 0630 3 0495...

Page 19: ...du dt Filters Installation Guide 19 Dimensional drawings AOCH0260 70 single phase filter du dt filter kit includes 3 pieces of single phase filters...

Page 20: ...du dt Filters Installation Guide 20 AOCH0260 70 15 9 kg 35 1 lbs 227 A rms 74 H Weight I TH L 3x 3x185 M12 147 W Cable size Screw size Power loss...

Page 21: ...du dt Filters Installation Guide 21 AOCH0400 70 single phase filter du dt kit includes 3 pieces of single phase filters...

Page 22: ...du dt Filters Installation Guide 22 AOCH0400 70 20 7 kg 45 6 lbs 355 A rms 52 H Weight I TH L 3x 3x185 M12 250 W Cable size Screw size Power loss...

Page 23: ...du dt Filters Installation Guide 23...

Page 24: ...du dt Filters Installation Guide 24 NOCH0760 60 Weight 43 kg 95 lbs 1 1 2 1 1 2 2 2...

Page 25: ...du dt Filters Installation Guide 25...

Page 26: ...du dt Filters Installation Guide 26 64787845 A NOCH0120 62 NOCH0120 65 Weight 45 kg 99 lbs...

Page 27: ......

Page 28: ...P O Box 184 FIN 00381 HELSINKI FINLAND Telephone 358 10 22 11 Fax 358 10 22 22681 Internet http www abb com ABB Inc Automation Technologies Drives Motors 16250 West Glendale Drive New Berlin WI 53151...

Reviews: