Parameters List 43
EN
TR
ZH
46.05 Current scaling
0…30000
A
10000
46.06 Speed ref zero scaling
0.00...30000.00
rpm
0.00
46.07 Frequency ref zero scaling
0.00...1000.00
Hz
0.00
46.11 Filter time motor speed
2…20000
ms
500
46.12 Filter time output frequency
2…20000
ms
500
46.13 Filter time motor torque
2…20000
ms
100
46.14 Filter time power
2…20000
ms
100
46.21 At speed hysteresis
0.00...30000.00
rpm
50.00
46.22 At frequency hysteresis
0.00...1000.00
Hz
2.00
46.31 Above speed limit
0.00...30000.00
rpm
1500.00
46.32 Above frequency limit
0.00...1000.00
Hz
50.00
46.41 kWh pulse scaling
0.001...1000.000
kWh
1.000
46.43 Power decimals
0...3
-
2
46.44 Current decimals
0...3
-
1
49 Panel port communication
49.01 Node ID number
1…32
-
1
49.03 Baud rate
1...5
-
115.2 kbps[4]
49.04 Communication loss time
0.3...3000.0
s
10.0
49.05 Communication loss action
0...3
-
Fault[1]
49.06 Refresh settings
Done[0], Configure[1]
-
Done[0]
50 Fieldbus adapter (FBA)
50.01 FBA A enable
Disable[0], Enable[1]
-
Disable[0]
50.02 FBA A comm loss func
0...5
-
No action[0]
50.03 FBA A comm loss t out
0.3...6553.5
s
0.3
50.04 FBA A ref1 type
-
-
Speed or
frequency[0]
50.05 FBA A ref2 type
Not applicable.
50.06 FBA A SW sel
Auto[0], Transparent mode[1] -
Auto[0]
50.07 FBA A actual 1 type
-
-
Speed or
frequency[0]
50.08 FBA A actual 2 type
Not applicable
50.09 FBA A SW transparent source
-
-
Not selected
50.10 FBA A act1 transparent source
-
-
Not selected
50.11 FBA A act2 transparent source
Not applicable.
50.12 FBA A debug mode
Disable[0], Fast[1]
-
Disable
50.13 FBA A control word
0.0.0.0.0...FF.FF.FF.FF
-
0.0.0.0
Index
Name
Range/List
Unit
Default
38.4 kbps[1]
57.6 kbps[2]
86.4 kbps[3]
115.2 kbps[4]
230.4 kbps[5]
No action[0]
Fault[1]
Last speed[2]
Speed ref safe[3] - Not applicable.
No action[0]
Fault[1] Last speed[2]
Speed ref safe[3]
Fault always[4]
Warning[5]
Speed or frequency[0]
Transparent[1]
General[2] Speed[4] Frequency[5]
Note:
Applicable only when
is disabled. If parameter MPPT reference is
enabled, then the parameter should be set to it’s default value.
Speed or frequency[0]
Transparent[1]
General[2] Speed[4] Frequency[5]
Note:
Applicable only when
is disabled. If parameter MPPT reference is
enabled, then the parameter should be set to it’s default value.
ACQ80R0-R8 QIG.book Page 43 Friday, February 1, 2019 1:18 PM