Ratings and fuses
I
II
III
IV
Type
ACQ580
Input
rating
Output ratings
Heat
dissipation
Air flow
Frame
size
Nominal use
-01-
I
1N
I
N
P
N
A
A
kW
W
m
3
/h
3-phase
U
N
= 400 V
(380…415 V)
088A-4
88
88
45
1240
139
R5
106A-4
106
106
55
1510
139
R5
3AXD00000586715.xls H
Type
ACQ580
Input
rating
Output ratings
Heat
dissipation
Air flow
Frame
size
Nominal use
Heavy duty use
-01-
I
1N
I
Ld
P
Ld
I
Hd
P
Hd
A
A
hp
A
hp
W
ft
3
/min
3-phase
U
N
= 480 V
(440…480 V)
088A-4
77
77
60
65
50
1240
82
R5
106A-4
96
96
75
77
60
1510
82
R5
3AXD00000586715.xls H
Type
ACQ580
-01-
gG
I
N
I
2
t
Voltage rating
ABB type
Type
IEC 60269
A
A
2
s
V
3-phase
U
N
= 400/480 V
(380…415 V, 440…480 V)
088A-4
100
65000
500
OFAF000H100
000
106A-4
125
103000
500
OFAF00H125
00
3AXD00000586715.xls H
Type
ACQ580
-01-
uR or aR
I
N
I
2
t
Voltage rating
Bussmann type
Type
IEC 60269
A
A
2
s
V
3-phase
U
N
= 400/480 V
(380…415 V, 440…480 V)
088A-4
160
16000
690
170M1569
000
106A-4
200
15000
690
170M3815
1
3AXD00000586715.xls H
3AXD50000035755 Rev A
Summary of Contents for ACQ580-01 Series
Page 12: ... 2016 ABB Oy All Rights Reserved 3AXD50000035755 Rev A MUL EFFECTIVE 2016 03 15 ...
Page 16: ...16 R0 R4 R5 R6 R9 EN DA DE ES FI FR IT NL PL PT RU SV TR ZH ...
Page 22: ...22 R0 R4 R5 R6 R9 EN DE ES FR IT RU SV 4 3 3 R4 3 3 4 ...
Page 88: ...88 R0 R4 R5 R6 R9 ...
Page 92: ...92I 1b 1a 2 IP21 IP55 R4 1b 1 1a 2 2 IP55 R0 R2 IP55 R3 1b 1a 2 3AXD50000035755 Rev A ...
Page 94: ... 2016 ABB Oy All Rights Reserved 3AXD50000035755 Rev A MUL EFFECTIVE 2016 03 15 ...
Page 106: ...106 R0 R4 R5 R6 R9 EN DE ES FR IT RU SV ...
Page 136: ...136 FI R5 Asennuksen pikaopas R0 R4 R5 R6 R9 FI DA DE ES FI FR IT NL PL PT RU SV TR ZH ...
Page 146: ...146 FR Guide d installation R5 R0 R4 R5 R6 R9 FR DA DE ES FI FR IT NL PL PT RU SV TR ZH ...
Page 168: ...168 R0 R4 R5 R6 R9 ...
Page 171: ...171 R5 Figures F 12 G 2 3 6 6 4 5 0 5 0 6 N m 0 5 0 6 N m 5 3 ...
Page 172: ...172 H 1b 1a IP21 IP21 IP55 1b 1 2 2b 2c 3 3b 8 3c 2a 3a 3AXD50000035755 Rev A ...
Page 174: ... 2016 ABB Oy All Rights Reserved 3AXD50000035755 Rev A MUL EFFECTIVE 2016 03 15 ...
Page 180: ...180 EN Quick start up guide R0 R4 R0 R9 EN DE ES FR IT RU SV ...
Page 198: ...198 FI Pika aloitusopas R0 R4 R0 R9 FI DE ES FR IT RU SV ...
Page 204: ...204 FR Guide de mise en route R0 R4 R0 R9 FR DE ES FR IT RU SV ...
Page 216: ...216 SV Snabbguide för idrifttagning R0 R4 R0 R9 SV DE ES FR IT RU SV ...