2.4

 

PoE connection 

 

If a PoE (Power Over Ethernet) network is available, the gateway can be configured to use 
it without any additional power supply.  

 

 

Figure 5 PoE network configuration 

 

From the Gateway Basic Page select: 

-

 

Connection Priority: Wired 

-

 

IP Allocation: DHCP or Static (in case the IP allocation is given) 

 

Press Apply at the bottom of the screen.  

 

 

 

Summary of Contents for Ability Smart Sensor

Page 1: ...DOCUMENT ID REV DATE LANG PAGE 9AKK107046A4620 G April 2020 EN 1 17 Copyright 2020 ABB All rights reserved TECHNICAL DOCUMENT ABB Ability Smart Sensor gateway Installation manual ...

Page 2: ...Table of contents 1 GENERAL 3 2 INSTALLATION 4 2 1 Prerequisites for installation 4 2 2 Recommended location 5 2 3 Gateway configuration 6 2 4 PoE connection 9 2 5 LAN Ethernet cable connection 10 2 6 WIFI connection 11 2 7 USB mobile dongle connection 12 2 8 Firewall configuration 13 2 9 Verifying the configuration 14 3 TROUBLESHOOTING 15 ...

Page 3: ...nternet access before it can start reading the Smart Sensors Following Internet connections are supported LAN Ethernet network together with PoE injector 2 4GHz WIFI network 3G 4G Mobile network with specific USB dongle The sales package includes X1000 Bluetooth router wall and pole mounting kits and a quick guide Figure 1 Content of the sales package For general information about the Cassia gatew...

Page 4: ...TT bypass function TCP HTTP 80 Mandatory Access Controller AC OUT Container APP download from AC TCP HTTPS 443 Mandatory Smart Sensor Platform OUT Communication with Smart Sensor Platform Container APP download from AC TCP 9999 Mandatory Access Controller AC OUT Remote SSH to container UDP 53 Mandatory DNS server OUT DNS lookup for AC address The above table is considered from gateway perspective ...

Page 5: ...gles For the list of supported dongles please check the section 2 7 USB mobile dongle connection SIM card with Internet data plan Gateway also supports the use of any USB powered WIFI modems Mounting Flat head screwdriver for pole mounting Phillips head screwdriver and a drill if needed for wall mounting Mounting is not mandatory but it is recommended to secure the gateway somehow to its intended ...

Page 6: ...nect to this WIFI hotspot with the device used for configuration computer phone or tablet and open the web browser Type 192 168 40 1 to the web browser s address field and press enter Cassia configuration page will open During the first login the default password needs to be changed Default credentials are Login admin Password admin Figure 2 Cassia login page It is recommended to replace the defau...

Page 7: ...n for all network configurations PoE LAN WIFI Mobile AC Server Address abb cassia pro AC Server Address for China gw smartsensor abb com cn Remote Assistance ON Router Mode AC Managed Router AC Router Comm Ports 5246 5247 Connection Priority is where a priority connection method is selected in case there are several in use Select the priority according to connection in use Wired for PoE and LAN co...

Page 8: ...ABB ABILITY SMART SENSOR GATEWAY DOCUMENT ID REV DATE LANG PAGE 9AKK107046A4620 G April 2020 EN 8 17 Copyright 2020 ABB All rights reserved 3G 4G for mobile USB dongle connection Figure 4 Basic page ...

Page 9: ... 4 PoE connection If a PoE Power Over Ethernet network is available the gateway can be configured to use it without any additional power supply Figure 5 PoE network configuration From the Gateway Basic Page select Connection Priority Wired IP Allocation DHCP or Static in case the IP allocation is given Press Apply at the bottom of the screen ...

Page 10: ...hernet cable connection If a LAN Ethernet network is available the gateway can be configured to use it Additional PoE injector is needed for power supply Figure 6 LAN network configuration From the Gateway Basic Page select Connection Priority Wired IP Allocation DHCP or Static in case the IP allocation is given Press Apply at the bottom of the screen ...

Page 11: ... configured WIFI network In case the DHCP is used the gateway has now a new IP address This IP address is needed to reconnect to the gateway e g to check the Status Page or scan the devices within the gateway s range Local IT department can find out the gateway s IP address by accessing the WIFI router device list or by performing the network scan for IP addresses In case a static IP is used the a...

Page 12: ...way Basic Page select Connection Priority 3G 4G USB Dongle Type select correct dongle type used Type the access point name APN which the SIM carrier is using Type the username and password for the APN if needed Press Apply at the bottom of the screen Reboot the gateway by removing the power supply for a few seconds and then reconnecting it NOTE With a USB dongle the gateway needs to be in place wh...

Page 13: ...e of certain types of hardware providers ex Check if Huawei can be used in the US 2 8 Firewall configuration In case there is a firewall in the network which the gateway is using specific ports need to be opened Figure 9 Firewall Configuration for Global Figure 10 Firewall configuration for China Firewall should allow communication between the gateway and Access Controller and gateway and Smart Se...

Page 14: ...connection Reboot the gateway power off on Connection to Access controller can be verified also with Debug Tools in Other tab abb cassia pro Time 5s and press Start To check connection to Access Control ler select Ping add Address abb cassia pro or gw smartsensor abb com cn in case of China To verify UDP ports open close status select netcat add Address abb cassia pro or gw smartsensor abb com cn ...

Page 15: ...odel is supported by the gateway and that the dongle has established a connection to a mobile network Check that the used network does not use VPN Check the used network firewall settings The necessary ports need to be open for outbound communication Gateway is not reading the Smart Sensor data Check that the Smart Sensors are within the gateway s range Gateway is reading the data from Smart Senso...

Page 16: ...work generated by the gateway If the gateway is connected to WIFI then connect the configuration device to the same WIFI network as the gateway is connected Type in the gateway s MAC and IP addresses to the fields Router MAC and Router IP Press Start Scan Debug Tool now starts to list all Bluetooth devices within its range For all scanned devices the tool is showing the MAC address and RSSI value ...

Page 17: ... 2020 ABB All rights reserved RSSI value 80 or less is poor most probably the sensor cannot be read If the desired Smart Sensors are showing RSSI values of 70 or less it is recommended to adjust the gateway s location or orientation For more support please contact Smart Sensor support support smartsensor abb com ...

Reviews: