ABB-Welcome
|
— 9 —
Pos: 70 /Di nA4 - A nleitu ngen Onlin e/Ueb ersc hrift en/2 ./Ge raet eeins tellun gen @ 1 8\mo d_1 302 768 847 744 _15. docx @ 10 354 8 @ 2 @ 1
4.3
Adjusting the device
Pos: 71 /Di nA4 - A nleitu ngen Onlin e/Ueb ersc hrift en/3 ./Abschl usswide rsta nd @ 19\ mod _13 219 5807 990 6_1 5.do cx @ 1100 83 @ 3 @ 1
Pos: 72 /Di nA4 - A nleitu ngen Onlin e/In halt/KNX/Do orEnt ry/Bedie nun g/Abschl usswide rsta nd s etzen 83 220 -AP-xxx @ 19\ mod _13 1072 339 236 9_1 5.do cx @ 1 078 41 @ @ 1
Fig. 2:
Pos: 74 /Di nA4 - A nleitu ngen Onlin e/In halt/KNX/Do orEnt ry/Bedie nun g/M aste r/Slave Sc halte r setz en 832 20-AP-xxx @ 1 9\m od_1 310 723 320 966 _15. docx @ 10 783 3 @ @
1.
Station
Press selector switch to set the address of default outdoor station.
2.
X10 X1
Press selector switches to set the address (tens and units digits) of the indoor
station.
X100 X200
Set through “light” button.
3.
Master/Slave function
One indoor station in each apartment must be set as "Master." (Switch should be
set as “M/S on.”) All additional indoor stations in the same apartment must be set
as "Slave." (Switch should be set as “M/S off.”)
4.
Terminal resistor
In video installations or mixed audio and video installations, the Switch must be
set as “RC on” on the last device of the line.
5.
a b
= Bus connection
= Doorbell connection