Set indoor station address (X200, X100)
Pos: 28 /Di nA4 - A nleitu ngen Onlin e/In halt/KNX/Do orEnt ry/83 220 -AP-xxx/Sp rech - u nd Vide over bind ung - 8 322 0-AP-xxx @ 20\ mo d_1 3232 623 418 52_ 15.d ocx @ 111 919 @ @ 1
Step 1: Hold "light"
button for 3s to enter setting mode. (4 LEDs are on)
Step 2: Hold "talk"
button for 3s to enter the setting of X200/X100.
Step 3: Press "mute"
button to change the number.
The value is indicated by LED of each button.(Default value =0)
LED "talk" flashes, 0xx.
LED "unlock" flashes, 1xx.
LED "light" flashes, 2xx;
.
Step 4: Hold "light"
button for 3s to enter setting mode (4 LEDs are off)
4.2.2
Set function of light button
Step 1: Hold "light"
button for 3s to enter setting mode (4 LEDs are on)
Step 2: Hold "unlock"
button for 3s to enter the setting of light button.
Step 3: Press "mute"
button to change the function.
The value is indicated by LED of each button.(Default value =0)
LED "talk" flashes, switching the lighting.
LED "unlock" flashes, opening the second lock.
LED "light" flashes, room to room intercom.
LED "mute" flashes, call guard unit.
Step 4: Hold "light"
button for 3s to enter setting mode (4 LEDs are off)
024
124
224
24