ABB 600T Series Operating	 Instruction Download Page 2

- 2 -

The Company

ABB is an established world force in the design and manufacture of 
instrumentation for industrial process control, flow measurement, gas and 
liquid analysis and environmental applications.

As a part of ABB, a world leader in process automation technology, we offer 
customers application expertise, service and support worldwide.

We are committed to teamwork, high quality manufacturing, advanced 
technology and unrivalled service and support.

The quality, accuracy and performance of the Company’s products result 
from over 100 years experience, combined with a continuous program of 
innovative design and development to incorporate the latest technology.

The NAMAS Calibration Laboratory No. 0255(B) is just one of the ten flow 
calibration plants operated by the Company, and is indicative of ABB 
dedication to quality and accuracy.

Use of Instructions

 Warning. 

An instruction that draws attention to the risk of injury 

or death.

 Caution. 

An instruction that draws attention to the risk of damage 

to the product, process or surroundings.

Although 

Warning 

hazards are related to personal injury, and 

Caution 

hazards are associated with equipment or property 

damage, it must be understood that operation of damaged equipment could, under certain operational conditions, result 
in degraded process system performance leading to personal injury or death. Therefore, comply fully with all 

Warning 

and 

Caution 

notices.

Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this 
manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without 
prior approval of Technical Communications Department ABB.

BS EN ISO 9001

St Neots, U.K. – Cert. No. Q5907
Stonehouse, U.K. – Cert. No. FM 21106

Stonehouse, U.K. – Cert. No. 0255

UNI EN 29001 (ISO 9001)

Lenno, Italy – Cert. No. 9/90A

V

 Note. 

Clarification of an instruction or additional information.

 Information. 

Further reference for more detailed information or 

technical details.

ABB

Health and Safety

To ensure that our products are safe and without risk to health, the following points must be noted:
1.  The relevant sections of these instructions must be read carefully  before proceeding.
2.  Warning labels on containers and packages must be observed. 
3.  Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with 

the information given.

4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high 

pressure and/or temperature.

5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling 

procedures must be used.

6.  When disposing of chemicals ensure that no two chemicals are mixed.

Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable 
may be obtained from the Company address on the back cover, together with servicing and spares information.

Summary of Contents for 600T Series

Page 1: ...1 Operating instruction IM 695FI_8 600T EN Series Model 695FI Field Indicator ASEA BROWN BOVERI...

Page 2: ...his manual is intended only to assist our customers in the efficient operation of our equipment Use of this manual for any other purpose is specifically prohibited and its contents are not to be repro...

Page 3: ...tes shown below The Nameplate provides information concerning the product code theinputsignal theproductserialnumber seeRef A Please refer to this number when making enquiries The Safety Marking plate...

Page 4: ...ter s terminal block fig 3 2 Junction box i e inserted in any point of the 4 to 20 mA line connecting the transmitter to its receiver power supply fig 4 In any cases the line resistance to the field i...

Page 5: ...EMOTE METER M Fig 3 Fig 4 To receiver power supply To receiver power supply 695FI as indicator only 695FI as junction box 2600T transmitter terminal block 2600T transmitter terminal block Fig 3a Fig 4...

Page 6: ...y in place screw on the cover and tighten WARNING ForHazardousAreasinstallations the connection of cables and conduits to the indicator shall be made in accordance with the requirements of the relevan...

Page 7: ...r itself and the transmitter can be configured ProMeter is only programmable In fact two are the main menu ConF METER and ConF XMTR ACCESS TO CONFIGURATION To enter these men for both indicators the k...

Page 8: ...itterconnected Before accepting the transmitter configuration by pressing ENTERattherequest ConFUPDATE itispossibletoview the LRV ZERO the URV FULL SC and the UNIT If the output transfer function of t...

Page 9: ...g the transmitter information See below a list of the available operation under the selected option CONF menu TRIM menu REVIEW menu PV menu Change LRV Reranging RERANG TAG 8 Primary variable PRIMARY C...

Page 10: ...UT 12000 OUT mA ENTER MANUAL ENTER SET 4mA ENTER 04 000 04 000 04 000 04 000 04 000 REF V AL 4 000 REF TX ENTER SET20 mA ENTER ENTER 20 000 20 000 20 000 20 000 20 000 REF V AL 20 000 REF TX ENTER ENT...

Page 11: ...ESC 0 000 LR V ESC 40 000 UR V ESC 40 000 LRL ESC 40 000 URL ESC 1 0000 DAMPING ESC OUTPUT LIN ESC ENTER ESC NEXT PREV NEXT PREV Fig 11 PV menu ENG UNITS PV ENTER PRIMAR Y ESC ENTER 10 sec 10 690 KP A...

Page 12: ...max span 16 mA EMI RFI Total effect 0 10 from 20 to 1000 MHz and for field strengths up to 10 V m when instrument is properly in stalled Input range 4 to 20 mA nominal Operating range 3 6 to 22 mA for...

Page 13: ...certificate number 01ATEX015 The meaning of ATEX code is as follows II Group for surface areas not mines 1 or 2 Category G Gas dangerous media D Dust dangerous media T50 C Maximum surface temperature...

Page 14: ...he number close to the CE marking of the indicator safety label identifies the Notified Body which carries out the Surveillance for the production of the indicator The other marking refers to the prot...

Page 15: ...surement Also liquid level and temperature I to P Converters and Field Indicators Flow Metering Magnetic Flowmeters Electromagnetic insertiontypeprobesandwatermeters Turbine Flowmeters Wedge Flow Elem...

Page 16: ...Ltd Howard Road St Neots Cambridgeshire PE19 3EU UK Tel 44 0 1480 475321 Fax 44 0 1480 217948 ABB Inc 125 E County Line Road Warminster PA 18974 USA Tel 1 215 674 6000 Fax 1 215 674 7183 ABB SpA Meas...

Reviews: