ABB-Welcome
Operation
|
— 37 —
5.4
Keypad outdoor station
5.4.1
Call a resident (3 types)
1.
By physical address
Physical address is the internal code which the outdoor
station will send through the bus connection to indoor
stations or other devices in the system. For each
apartment, physical address means the address of an
indoor station which is installed in the apartment. For
each building, physical address means the address of a
gateway which is installed for each building, and it is
also called the building number.
In standby mode, a visitor can press the physical
address corresponding to the residence that you want to
call directly, from 001 to 250.
For a complex building, a visitor needs to press the
building number (01~60) + physical address (001~250)
or make a call in the gate station.
Fig. 23
2.
By logic address
Logic address is a code that a visitor can press to make a call. The code must be
assigned first and then associated with the physical address.
The apartment No. or some special codes can be used to set the logic address, which is
easy for the users to remember.
Set the logic address by taking the following steps:
Assign the logic address:
#* system password #
=>
system setting
=>
Address Book
=>
Add
=>
Logic Add
Enter Physical A
dd.:
01 001
Summary of Contents for 5102xDN Series
Page 9: ...ABB Welcome Terminal description 9 4 1 1 Lock connected with terminals 3 4 ...
Page 10: ...ABB Welcome Terminal description 10 4 2 Camera module Fig 3 Terminal description ...
Page 13: ...ABB Welcome Terminal description 13 ...
Page 15: ...ABB Welcome Terminal description 15 ...
Page 59: ...ABB Welcome Mounting Installation 59 Cover frame ...
Page 60: ...ABB Welcome Mounting Installation 60 Flush mounted box ...
Page 61: ...ABB Welcome Mounting Installation 61 Rain hood ...