12 Troubleshooting
Vacuum can not be generated.

Possible cause

Aktion

Vacuum pump doesn’t work correctly.

Check vacuum pump for operation.

Hose or pipe isn’t connected correctly.

Check hose and pipe for correct connection.

Spiral or hydraulic hose is leaking.

Replace the spiral or the hydraulic hose by a new one.

Ball valve at expansion tank is opened.

Make sure that ball valve at expansion tank is closed.

Expansion tank is leaking.

Check that expansion tank bottom and top plates are screwed tight together.

 
 
13 Disposal
The vacuum pump set consists of materials which may be recycled. The main components are aluminum  
and plastics.
However, most of the components are directly in contact with hydraulic oil. Observe the local regulations  
for this case. In doubt contact the local ABB representative.

14  Technical data

Parameter

Value Unit

Voltage

110-120 / 220-240 V

Frequency

50 / 60 Hz

Minimum pressure

0,01 bar

Temperature range (operation)

0...+50 °C

Temperature range (storage)

+5...+40 °C

Dimensions

280 x 460 x 580 mm

Total weight

21 kg

15  Manufacturer information 
ABB AG
High Voltage Products 
Brown-Boveri-Strasse 30
63457 Hanau, Germany

For any assistance, support or service we recommend to contact directly our local representatives first.  
They have extensive knowledge of the specific customer needs, the individual circumstances and the  
possibilities of the whole ABB group and are consequently able to organize an optimal service.

Information
In case of an ABB Power Care contract the customer is able to use our 24-h hotline for free. In case of  
emergency our troubleshooting experts offers a fast and reliable support. 

24-h hotline: +49 (0) 180 6222 007

Please have the following information ready when calling our 24-h hotline:
•  Your contact details 

 

 

•  Bay no

•   Designation of station   

 

•  Module no

•  Order / Serial No 

 


Spare part list

Part

Number

Vacuum pump 110/230 V, 50/60 Hz

1HDS112161R0001

Expansion tank 1.5 l

1HDS112166R0001

Spiral hose 7.5 m

1HDS112167P0001

Pressure gauge

1HDS112171R0001

Pipe connection 150 mm

1HDS112165R0001

Pipe connection 50 mm

1HDS112165R0002

Tank connection adapter G3/4“

1HDS112023P0125

Tank connection adapter G3/8“

9ABA460090P2080

Pipe connection adapter 10S

1HDS112177P0001

Hydraulic hose 1 m

1HDS112176P0001

11 Maintenance

Summary of Contents for 1HDS112160R0001

Page 1: ...ydromechanical operating mechanisms Product manual 1HDS680632 REV A The vacuum pump set 1HDS112160R0001 is designed to evacuate hydromechanical operating mechanisms of type AHMA and HMB in mounted discharged condition before commissioning 01 Vacuum pump set ...

Page 2: ...iated documents 3 4 Scope of delivery 3 5 Safety instructions 4 6 Standards and directives 4 7 Shipping and storage 4 8 Commissioning 4 9 Technical information 5 10 Operating instructions 5 11 Maintenance 6 12 Troubleshooting 6 13 Disposal 6 14 Technical data 6 15 Manufacturer information 6 Declaration of conformity ...

Page 3: ...anual 2 Abbreviations AHMA Hydromechanical operating mechanism type A CO Close Open COV Change over valve HMB Hydromechanical operating mechanism type B SF6 Sulphur hexafluoride 3 Associated documents Technical description of oil handling kit 1HDS680617P0001 Instruction for operation and maintenance 1HDH118041 or comparable 4 Scope of delivery The vacuum pump set will be delivered in a transportat...

Page 4: ... new parts The device shall only be repaired by the manufacturer For following switching operations of the operating mechanism on the coupled breaker it has to be secured that the switching device is filled with SF6 gas at appropriate operating pressure The mnimal oil level at fully charged operating mechanism should not be lower than the oil level given in the oil level charts of the technical de...

Page 5: ...witching characteristics e g simultaneity The mentioned pressure ranges are absolute pressure values e g 50 mbar absolute The provided pressure gauge has a relative pressure sensor display Consequently a conversion of absolute to relative pressure values with regard to the ambient atmospheric pressure is necessary 10 Operating instructions 1 Open the tank connection of the low pressure tank 2 Conn...

Page 6: ...460 x 580 mm Total weight 21 kg 15 Manufacturer information ABB AG High Voltage Products Brown Boveri Strasse 30 63457 Hanau Germany For any assistance support or service we recommend to contact directly our local representatives first They have extensive knowledge of the specific customer needs the individual circumstances and the possibilities of the whole ABB group and are consequently able to ...

Page 7: ......

Page 8: ...to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility whatsoever for poten tial errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without p...

Reviews: