Physical Characteristics
Outline Dimensions, Magnetic
Flowmeter with or without
integral Signal Converter
Standard with Sanitary Fittings
25 - 40 mm (1 - 1-1/2")
See Figure 2-1 See Figure 2-3
50 - 100 mm (2 - 4")
See Figure 2-2 See Figure 2-4
Remote Mounted Signal
Converter
See Signal Converter Instruction Bulletin
Conduit Connections
(2) 1/2" NPT internally threaded entrances in pri-
mary junction box
Meter Weight
Remote Mounted Signal
Converter
See Signal Converter Instruction Bulletin
Materials of Construction
Meter Body (Spool)
Ceramic, 99.5% Alumina
Electrode Assemblies
(non-wetted)
Capacitive Pickup
Meter Housing
carbon steel, all welded construction, epoxy finish
Housing End Rings
304 sst
Electronics Housing
die cast aluminum, epoxy finish, 316 sst attach-
ment screws, 1/2 NPT conduit connections,
gasketed covers
Installation Kit
includes 2 gaskets, mounting studs and nuts,
flange adaptor device(s) as required.
Exception: Sanitary TRI-CLAMP Fittings
Meter is preassembled; all mounting hardware
(studs and nuts) and flanges are stainless steel.
Gaskets are TEFLON-FEP (Virgin). Gasket
manufacturer must provide certificate of
compliance as proof of and compliance with 3A
Sanitary Standards, Class-I material.
10D1477 MAGNETIC FLOWMETER INSTRUCTION MANUAL
1-8
Summary of Contents for 10D1477
Page 18: ...FIGURE 2 1 OUTLINE DIMENSIONS 1 1 1 2 SIZES 10D1477 MAGNETIC FLOWMETER INSTRUCTION MANUAL 2 3 ...
Page 19: ...FIGURE 2 2 OUTLINE DIMENSIONS 2 4 SIZES 10D1477 MAGNETIC FLOWMETER INSTRUCTION MANUAL 2 4 ...
Page 49: ...FIGURE 6 1 BASIC FLOWMETER PARTS 10D1477 MAGNETIC FLOWMETER INSTRUCTION MANUAL 6 6 ...