1.8.4 Stopping distance / time
General
Stopping distance/time for emergency stop (category 0), program stop (category1)
and at main power supply failure at max speed, max stretched out and max load,
categories according to EN 60204-1. All results are from tests on one moving axis.
All stop distances are valid for floor mounted robot, without any tilting.
IRB 1200-5/0.9
IRB 1200-7/0.7
Stopping dis-
tance (º)
Stop time (s)
Stopping dis-
tance (º)
Stop time (s)
49
0.24
36
0.23
Axis 1
Category 0
40
0.29
28
0.24
Axis 2
53
0.34
22
0.21
Axis 3
70
0.41
75
0.43
Axis 1
Category 1
66
0.34
46
0.40
Axis 2
53
0.36
34
0.40
Axis 3
42
0.25
49
0.25
Axis 1
Main power
failure
54
0.31
29
0.22
Axis 2
33
0.21
34
0.31
Axis 3
Product specification - IRB 1200
45
3HAC046982-001 Revision: G
© Copyright 2017 ABB. All rights reserved.