3. Select a safety factor (SF). Most users build-in between 10% (SF = 1.1) and 25% (SF =

1.25), or more. If you don’t wish to use a SF, proceed to Step 4.

4. Calculate the minimum total airflow required (Total CFM), as follows:

Total CFM = (V x ACH x SF) 

÷

 60.

5. # Units Required = Total CFM 

÷

 CFM rating for the Unit.

6. Always round up to the next whole number. For example, if the minimum requirement is 2.1

units, 3 units are recommended, not 2.

Example 1:

How many 900 CFM units are needed to provide at least 6 ACH in a 25’ x 30’ x 10’ containment area,
with a 20% safety factor?
   V = 25 x 30 x 10 = 7,500 Cubic Feet
   Total CFM = (7,500 x 6 x 1.2) 

÷

 60 = 900 CFM

   Minimum # PAS Units Req’d = 900 CFM 

÷

 900 CFM 

(airflow of unit)

 = 

1 Unit  Required

Example 2:

How many 900 CFM units are needed to provide at least 5 ACH in a 50’ x 42’ x 10’ containment area,
with a 25% safety factor?

 V = 50 x 42 x 10 = 21,000 Cubic Feet
Total CFM = (21,000 x 5 x 1.25) 

÷

 60 = 2,188 CFM

Minimum # Units = 2,188 

÷

 900 = 2.4 = 

3 Units Required

Note: This example illustrates the importance of a Safety Factor. If no SF were used, only 1,750
CFM (2 units) would be required.

PAS1200 TRANSPORT

Note

:  The PAS1200 can be transported in the horizontal position.  If extremely poor road conditions

exist, or excessive shock and vibration are expected, take precautionary measures by padding the
unit to provide impact absorption during transport.

Caution

:  Always use caution when moving the PAS1200 inside a building or home.  The unit weighs

85 pounds.  Older structures with weakened floors or staircases may require special considerations
for safe transport.

ELECTRICAL REQUIREMENTS

1.   The PAS1200 requires a minimum of 110 volts AC, 60 Hz to operate properly; however,

maximum airflow performance requires 120 volts AC, 60 Hz.

2.   Due to momentary start-up current surge, the unit requires a 15 amp circuit that is free of other

loads.

3.   Extension cords used for the PAS1200 must be UL listed, heavy duty No. 14/3 AWG industrial

grade 3-wire type. Use of larger numerical gauge (lower capacity wire) power cord(s) may result
in electrical shock, fire hazards and/or damage to unit. The cord(s) must be in good condition
and in continuous lengths (no splicing) and should not exceed a total of 50 feet in length.

 Make

certain that any extension cords used do not reduce power to the unit to less than 110 volts. Use
of a voltmeter to confirm adequate voltage is recommended.

4.   Check to ensure that any circuit to which the unit is connected is protected by a 15 ampere

circuit breaker. The unit itself is equipped with a 10 amp circuit breaker.

Summary of Contents for PAS1200

Page 1: ...M M M M ModelP odelP odelP odelP odelPAS1200 AS1200 AS1200 AS1200 AS1200 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL Abatement Technologies Ltd Ontario Canada 905 871 4720 Abatement Technologies Inc Georgia USA 800 634 9091 PAS1200MNI rev 6 29 2009 Abatement Technologies Inc Remediation Products Division www abatement com ...

Page 2: ... F621 2 Second Stage 2 Pleated Pre filter P N H502 3 OptionalThird Stage 2 High Capacity Carbon Filter P N VL1002 4 Final Stage 99 97 HEPA Filter P N H610C 99 5 Motorized Impeller 6 8 Rear Wheels 7 360 Swivel Casters 8 Prefilter Access Door 9 HEPA Filter Access Panel 10 Control Panel 11 Exhaust Outlet ...

Page 3: ...own as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Dust Drywall dust Saw dust Note To capture low concentrations of OVG a Vapor Lock carbon filter must be used The PAS1200 is capable of providing particulate and odor vapor gas filtration with final stage filtration through a High Efficiency ParticulateAir HEPA filter The PAS120...

Page 4: ... OVG and how do I know when a carbon filter should be replaced Unfortunately unknown factors such as concentration levels fresh air intake volume temperature and humidity prevent establishment of any more accurate rule of thumb than one s sense of smell Since off gassing of adsorbed OVG can occur when the adsorption capacity of the filter is reached replace the carbon filter as soon as odor breakt...

Page 5: ...emely poor road conditions exist or excessive shock and vibration are expected take precautionary measures by padding the unit to provide impact absorption during transport Caution Always use caution when moving the PAS1200 inside a building or home The unit weighs 85 pounds Older structures with weakened floors or staircases may require special considerations for safe transport ELECTRICAL REQUIRE...

Page 6: ...er cords with utility equipment and vehicles Important Safety Instructions a Do not operate any unit with a damaged cord or plug Discard unit or return it to an authorized service facility for examination and or repair b Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area ...

Page 7: ... Indicator Primary Amber light that indicates excessive restriction on air intake or loading of the pre filter s and that filter change procedures should be followed 6 Filter Change Indicator HEPA Amber light that indicates excessive restriction on air exhaust or loading of the HEPA filter and that filter change procedures should be followed 7 Circuit Breaker 10 amp circuit breaker that provides p...

Page 8: ...airborne contaminants from entering a containment area by keeping that area under positive pressure compared to adjacent spaces so any air leakage will be an outflow of clean air and not inflow of contaminated air This pressure differential can be established by a placing the unit inside the containment area and using it to pull air into the area by attaching flex duct between the inlet collar and...

Page 9: ...duction is generally the result of filter loading blockage of the unit s inlet or use of excessive lengths of flex duct that is connected to the inlet The size and concentration of airborne contaminants temperature and humidity conditions and duration of use determine how often filters need replacement If the Filter Change Indicator s on the control panel illuminate this indicates one or more of t...

Page 10: ...er and replace it with a new one 3 Close the door and lock it in position Note If an optional Vapor Lock filter is being used be sure to remove it from its poly bag before installing it in the unit Vapor Lock filters are packaged in poly bags to preserve the integrity of the carbon granules To Change the HEPA Filter 1 Turn the unit OFF and disconnect the power cord from the electrical outlet 2 Rem...

Page 11: ... w o l f g n i t a r e p O s r e t l i f n a e l c h t i w M F C 0 0 9 0 5 1 e l b a i r a V r e k a e r B t i u c r i C p m a 0 1 l e v e l d n u o s l a n o i t a r e p O t e e f 5 t a n e k a t g n i d a e r A B d 7 6 2 6 t e n i b a C s m a e S s t e v i r d i l o s h t i w d e l b m e s s a l e e t s s s e l n i a t s e g u a g 0 2 d e t e k s a g e r a y t i l i b a t r o p s n a r T l e v i...

Page 12: ... T S U A H X E R O N E E B T O N S A H R E T L I F N O B R A C G A B Y L O P M O R F D E V O M E R H T I W E C N A D R O C C A N I E G N A H C S N O I T C U R T S N I G N I T A R E P O T C U D X E L F F O H T G N E L S D N E B E C U D E R S N O I T C I R T S E R E T A N I M I L E R O M O R F R E T L I F N O B R A C E V O M E R G A B Y L O P Note If the unit does not start or malfunctions after car...

Page 13: ...nd by ATI to be free from defect and to conform to specifications shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damag...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Reviews: