ABATEMENT PAS1200 Instruction Manual Download Page 3

2

HEPA-AIRE

®

®

®

®

®

 Portable Air Scrubber

Model: PAS1200

Instruction Manual

©

 Abatement Technologies 2003 All Rights Reserved.  No reproduction of any portion of this work is permitted

without the express written permission of Abatement Technologies, Inc.

READ AND SAVE THESE INSTRUCTIONS!

Note:   1.  Read and understand all operating instructions before using the PAS1200 Portable Air

Scrubber.

2. Save this manual for future reference.

This instruction manual provides important information on the use of the 

HEPA-AIRE

®

 

Portable Air

Scrubber 

(PAS) - model PAS1200.  These instructions must be carefully followed in order to operate

the unit safely and correctly.  If there are any questions regarding the use of the unit, please contact
Abatement Technologies immediately at 800-634-9091 U.S. or 905-871-4720 Canada.

Abatement Technologies strongly urges users of air filtration units and related accessories to follow
the most recent guidelines and/or standards published by the Occupational Safety and Health
Administration, Environmental Protection Agency, and all other federal, state, provincial and local
regulations.

GENERAL  INFORMATION

The PAS1200 is a multi-use air filtration device, equipped with pre-filters and a HEPA filter that are
capable of filtering many airborne contaminants. An optional carbon pre-filter for capturing low
concentrations of odors, vapors, gases, and volatile organic compounds, collectively known as OVG,
is also available.

Types of contaminants captured by particulate pre-filters, HEPA filter, or carbon filters:

• Dirt
• Dust
• Drywall dust
• Saw dust

Note: To capture low concentrations of OVG, a Vapor-Lock

®

 carbon filter must be used.

The PAS1200 is capable of providing particulate and odor, vapor, gas filtration with final stage filtration
through a High Efficiency Particulate Air (HEPA) filter. The PAS1200 incorporates a series of particulate
filters which successively remove larger size to smaller size particles from the air. In addition to
providing HEPA filtration, the PAS1200 is primarily used in a negative pressure or recirculation mode.
A negative pressure condition is created in order to confine contaminated airborne particles. This
condition exists when the static pressure inside the room containing the unit is lower relative to the
pressure of the environment outside the room. The static pressure differential is created and maintained
by continuously exhausting air out of a given room at a faster rate than air enters the room from all
other sources. In the recirculation mode, all of the filtered air is exhausted back into the room containing
the unit.

Standard Air Cleaning Stages (filters supplied with the unit)

The PAS1200 comes equipped with two progressively efficient particulate pre-filters mounted in the
pre-filter compartment, and a final stage HEPA filter, located in the lower section of the cabinet:

• Low concentrations of OVG

• 

Low concentrations of Volatile

  Organic Compounds (VOC)
• Unpleasant nuisance odors

• Lung-damaging particles
• Metal fumes
• Smoke
• Mold and fungal spores

Summary of Contents for PAS1200

Page 1: ...M M M M ModelP odelP odelP odelP odelPAS1200 AS1200 AS1200 AS1200 AS1200 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL Abatement Technologies Ltd Ontario Canada 905 871 4720 Abatement Technologies Inc Georgia USA 800 634 9091 PAS1200MNI rev 6 29 2009 Abatement Technologies Inc Remediation Products Division www abatement com ...

Page 2: ... F621 2 Second Stage 2 Pleated Pre filter P N H502 3 OptionalThird Stage 2 High Capacity Carbon Filter P N VL1002 4 Final Stage 99 97 HEPA Filter P N H610C 99 5 Motorized Impeller 6 8 Rear Wheels 7 360 Swivel Casters 8 Prefilter Access Door 9 HEPA Filter Access Panel 10 Control Panel 11 Exhaust Outlet ...

Page 3: ...own as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Dust Drywall dust Saw dust Note To capture low concentrations of OVG a Vapor Lock carbon filter must be used The PAS1200 is capable of providing particulate and odor vapor gas filtration with final stage filtration through a High Efficiency ParticulateAir HEPA filter The PAS120...

Page 4: ... OVG and how do I know when a carbon filter should be replaced Unfortunately unknown factors such as concentration levels fresh air intake volume temperature and humidity prevent establishment of any more accurate rule of thumb than one s sense of smell Since off gassing of adsorbed OVG can occur when the adsorption capacity of the filter is reached replace the carbon filter as soon as odor breakt...

Page 5: ...emely poor road conditions exist or excessive shock and vibration are expected take precautionary measures by padding the unit to provide impact absorption during transport Caution Always use caution when moving the PAS1200 inside a building or home The unit weighs 85 pounds Older structures with weakened floors or staircases may require special considerations for safe transport ELECTRICAL REQUIRE...

Page 6: ...er cords with utility equipment and vehicles Important Safety Instructions a Do not operate any unit with a damaged cord or plug Discard unit or return it to an authorized service facility for examination and or repair b Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area ...

Page 7: ... Indicator Primary Amber light that indicates excessive restriction on air intake or loading of the pre filter s and that filter change procedures should be followed 6 Filter Change Indicator HEPA Amber light that indicates excessive restriction on air exhaust or loading of the HEPA filter and that filter change procedures should be followed 7 Circuit Breaker 10 amp circuit breaker that provides p...

Page 8: ...airborne contaminants from entering a containment area by keeping that area under positive pressure compared to adjacent spaces so any air leakage will be an outflow of clean air and not inflow of contaminated air This pressure differential can be established by a placing the unit inside the containment area and using it to pull air into the area by attaching flex duct between the inlet collar and...

Page 9: ...duction is generally the result of filter loading blockage of the unit s inlet or use of excessive lengths of flex duct that is connected to the inlet The size and concentration of airborne contaminants temperature and humidity conditions and duration of use determine how often filters need replacement If the Filter Change Indicator s on the control panel illuminate this indicates one or more of t...

Page 10: ...er and replace it with a new one 3 Close the door and lock it in position Note If an optional Vapor Lock filter is being used be sure to remove it from its poly bag before installing it in the unit Vapor Lock filters are packaged in poly bags to preserve the integrity of the carbon granules To Change the HEPA Filter 1 Turn the unit OFF and disconnect the power cord from the electrical outlet 2 Rem...

Page 11: ... w o l f g n i t a r e p O s r e t l i f n a e l c h t i w M F C 0 0 9 0 5 1 e l b a i r a V r e k a e r B t i u c r i C p m a 0 1 l e v e l d n u o s l a n o i t a r e p O t e e f 5 t a n e k a t g n i d a e r A B d 7 6 2 6 t e n i b a C s m a e S s t e v i r d i l o s h t i w d e l b m e s s a l e e t s s s e l n i a t s e g u a g 0 2 d e t e k s a g e r a y t i l i b a t r o p s n a r T l e v i...

Page 12: ... T S U A H X E R O N E E B T O N S A H R E T L I F N O B R A C G A B Y L O P M O R F D E V O M E R H T I W E C N A D R O C C A N I E G N A H C S N O I T C U R T S N I G N I T A R E P O T C U D X E L F F O H T G N E L S D N E B E C U D E R S N O I T C I R T S E R E T A N I M I L E R O M O R F R E T L I F N O B R A C E V O M E R G A B Y L O P Note If the unit does not start or malfunctions after car...

Page 13: ...nd by ATI to be free from defect and to conform to specifications shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damag...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Reviews: