FEATURE IDENTIFICATION 

 

 

A. 

Foam gasket. The 1" thick foam 
gasket provides a seal against the 
ceiling when the header is raised to 
the ceiling. 

B. 

Header opening markers. In order to 
help align the unit, there are arrow 
marks on the outside of the header 
that indicate where the opening inside 
the unit begins and ends. Position the 
arrow furthest away from the door to 
align with the ceiling grid. 

C. 

12" x 12" window & pass-thru. A total 
of two clear windows allow visibility 
into and out of the fabric enclosure. 
The windows are attached via hook 
and loop on three sides, enabling it to 
be opened and act as pass-throughs 
for items such as pipe or conduit. 

D. 

Handles. A total of 8 handles are 
located at the corners of the mobile 
containment cart to assist in transport. 

E. 

Fiberglass extension ladder. The 
AIRE GUARDIAN® AG8000 was 
designed around the included 
fiberglass extension ladder and should 
only be used with this ladder. 

Read all 

warning and instruction labels 
located on the ladder as well as the 
instructions within this manual to 
properly operate the ladder.

 

F. 

Door. Door opening of 54.5" H x 22" 
W.  

G. 

Casters. This unit has 4 lockable 
swivel casters. 

 

Lockable  recessed  handle.  The  lockable  door  helps 
protect  tools  and  equipment  within  the  mobile 
containment cart when not in use. 

 

Note: 

To reduce the risk being locked out of the mobile 

cart, Abatement Technologies suggests making a copy of 
the key and storing the master in a secure place. 

 

Summary of Contents for AIRE GUARDIAN AG8000

Page 1: ...UCTION MANUAL Covered by one of more of the following U S Patent No 9 574 399 U S Patent No 10 195 979 Canada Patent No 2 895 016 Abatement Technologies Abatement Technologies Inc Georgia USA 1 800 63...

Page 2: ...echnologies at 1 800 634 9091 US or 1 905 871 4720 Canada for assistance or to request a digital copy of this manual Table of Contents Important Safety Instructions 1 General Information 3 Transportin...

Page 3: ...ways check to be certain no one is inside the unit before moving it Use only on level dry surfaces Do not use on slippery surfaces Do not put anything under the base or wheels of the AIRE GUARDIAN AG8...

Page 4: ...AG8000 is designed to be used with the provided extension ladder only and should not be used with any other ladder Read all instructions within this manual as well as all danger caution and instructi...

Page 5: ...items such as pipe or conduit D Handles A total of 8 handles are located at the corners of the mobile containment cart to assist in transport E Fiberglass extension ladder The AIRE GUARDIAN AG8000 was...

Page 6: ...luded K External receptacles The unit comes with a 3 prong male receptacle for connection to a 120V 60Hz power source that is used to power the female receptacles on the unit There is also a receptacl...

Page 7: ...with the remote variable speed knob that can be accessed while standing on the extension ladder R Internal GFCI receptacles One receptacle is designated for a PAS750 Portable Air Scrubber to allow re...

Page 8: ...access projects P N AG8000 SA Once installed the Side Access Panel and the original clear polycarbonate panel are interchangeable An optional Extension can be purchased to reach ceiling heights of 12...

Page 9: ...elp prevent over extending the header into the ceiling use the lowest clutch setting that is able to raise the header to the ceiling Turn hand crank clockwise to raise the header Turn hand crank count...

Page 10: ...nto the POWER SUPPLY outlet located on the back side of the unit and the male end into a 110V 120V 60Hz single phase outlet The AG8000 comes equipped with a power cord wrap that is located below the P...

Page 11: ...nd to maintain the minimum 75 angle required per OSHA requirements Opening and closing the top cover The top cover has a zipper down each long side and is secured by hook and loop on the short side ne...

Page 12: ...20VAC VARIABLE SPEED DEVICE ONLY as shown in the picture above If the PAS750 or PRED750 unit is located external to the AG8000 ensure it is plugged into the outlet labeled FOR 120VAC VARIABLE SPEED DE...

Page 13: ...n still be moved without crashing into any objects After raising the header close to the ceiling fine tune the positioning by aligning the arrow marker closest to the back of the unit with the ceiling...

Page 14: ...tor Locate the pressure monitor mounting bracket on the inside back wall of the AG8000 Remove the faceplate from the RPM series pressure monitor by unscrewing the two small screws on the sides of the...

Page 15: ...rovided hand crank or a power drill within a few inches of the ceiling Warning Be sure that the upper header will not crash into any device installed in the ceiling such as sprinkler heads sensors etc...

Page 16: ...ean with a mild water based cleaner or soap and water Do not use hydrocarbon based cleaners Do not place items on the vinyl enclosure Do not subject the vinyl enclosure to sharp or abrasive objects Be...

Page 17: ...eceptacles for general use 1 ea receptacle controlled by remove variable speed knob All receptacles rated 15 A entire circuit rated 15 A Scrubber speed control Remote variable speed control knob locat...

Page 18: ...the purchase price of such goods AT will pay return transportation charges on returned goods not exceeding the transportation charges applicable to shipment from original destination unless the return...

Page 19: ...18 EXTENSION LADDER WARNING AND INSTRUCTION LABELS...

Page 20: ...19 AG8000 WIRING DIAGRAM Starting Serial Number C800019402727...

Reviews: