15 

 

13. When finished with the ceiling work, replace the ceiling tile and close the top cover 

by zipping up the two zippers and engaging the hook and loop on the short edge 
near the ladder. 

14. Undo the hook and loop straps that secured the top of the ladder and then fully 

collapse the ladder. 

15. Before  exiting  the  unit,  be  sure  to  decontaminate  yourself  and  the  inside  of  the 

mobile containment cart using a HEPA filter vacuum. 

16. Completely lower top header of the unit with the raising/lowering mechanism with 

either the provided hand crank or a power drill. 

17. Unplug  the  power  supply  cord  and  wrap  the  cord  around  the  cord  wrap,  if 

necessary. 

18. Unlock all four of the casters by lifting the pedal on the casters up with your work 

shoe. 

19. Move the unit to the next desired location, being careful to avoid any contact with 

signs or devices mounted on the walls or ceiling. 

20. Repeat procedure starting from step 5, as needed. 

 

CARE OF THE UNIT 

 

  Clean with a mild water based cleaner or soap and water. Do not use hydrocarbon 

based cleaners. 

  Do not place items on the vinyl enclosure. 

  Do not subject the vinyl enclosure to sharp or abrasive objects. 

  Be sure all metal components are properly secured during transport and in storage 

so they cannot fall and cause personal injury or property damage. 

  Do not expose the vinyl enclosure to high heat. 

 

AIRE GUARDIAN® AG8000 SPECIFICATIONS 

 

FEATURE 

SPECIFICATION 

Weight with ladder 

325 lbs (147.4 kg) (air scrubber and pressure 
monitor not included) 

Maximum working ceiling 
height 

10'-2" [312 cm] 

Unit Height, Fully Collapsed 

6'-5.5" [196 cm] 

Unit Length x Width 

62" L x 32" W [157.5 cm L x 81.3 cm W] 

Header opening dimensions 

36" L x 22" W [91.4 cm L x 55.9 cm W] 

Door 

54.5" H x 22" W [138.5 cm H x 56 cm W] door 
opening; lockable handle 

Hardside wall material 

Clear polycarbonate provides visibility and allows 
light into the unit. 

Hardside wall material UL94 
flammability rating 

V0 

Fabric enclosure 

Fabric enclosure is removable and secured by hook 
and loop; includes two 12"x12" clear windows that 
each acts as a pass-through (window secured by 
hook and loop) (P/N: AG8000ENC-FR). 

Summary of Contents for AIRE GUARDIAN AG8000

Page 1: ...UCTION MANUAL Covered by one of more of the following U S Patent No 9 574 399 U S Patent No 10 195 979 Canada Patent No 2 895 016 Abatement Technologies Abatement Technologies Inc Georgia USA 1 800 63...

Page 2: ...echnologies at 1 800 634 9091 US or 1 905 871 4720 Canada for assistance or to request a digital copy of this manual Table of Contents Important Safety Instructions 1 General Information 3 Transportin...

Page 3: ...ways check to be certain no one is inside the unit before moving it Use only on level dry surfaces Do not use on slippery surfaces Do not put anything under the base or wheels of the AIRE GUARDIAN AG8...

Page 4: ...AG8000 is designed to be used with the provided extension ladder only and should not be used with any other ladder Read all instructions within this manual as well as all danger caution and instructi...

Page 5: ...items such as pipe or conduit D Handles A total of 8 handles are located at the corners of the mobile containment cart to assist in transport E Fiberglass extension ladder The AIRE GUARDIAN AG8000 was...

Page 6: ...luded K External receptacles The unit comes with a 3 prong male receptacle for connection to a 120V 60Hz power source that is used to power the female receptacles on the unit There is also a receptacl...

Page 7: ...with the remote variable speed knob that can be accessed while standing on the extension ladder R Internal GFCI receptacles One receptacle is designated for a PAS750 Portable Air Scrubber to allow re...

Page 8: ...access projects P N AG8000 SA Once installed the Side Access Panel and the original clear polycarbonate panel are interchangeable An optional Extension can be purchased to reach ceiling heights of 12...

Page 9: ...elp prevent over extending the header into the ceiling use the lowest clutch setting that is able to raise the header to the ceiling Turn hand crank clockwise to raise the header Turn hand crank count...

Page 10: ...nto the POWER SUPPLY outlet located on the back side of the unit and the male end into a 110V 120V 60Hz single phase outlet The AG8000 comes equipped with a power cord wrap that is located below the P...

Page 11: ...nd to maintain the minimum 75 angle required per OSHA requirements Opening and closing the top cover The top cover has a zipper down each long side and is secured by hook and loop on the short side ne...

Page 12: ...20VAC VARIABLE SPEED DEVICE ONLY as shown in the picture above If the PAS750 or PRED750 unit is located external to the AG8000 ensure it is plugged into the outlet labeled FOR 120VAC VARIABLE SPEED DE...

Page 13: ...n still be moved without crashing into any objects After raising the header close to the ceiling fine tune the positioning by aligning the arrow marker closest to the back of the unit with the ceiling...

Page 14: ...tor Locate the pressure monitor mounting bracket on the inside back wall of the AG8000 Remove the faceplate from the RPM series pressure monitor by unscrewing the two small screws on the sides of the...

Page 15: ...rovided hand crank or a power drill within a few inches of the ceiling Warning Be sure that the upper header will not crash into any device installed in the ceiling such as sprinkler heads sensors etc...

Page 16: ...ean with a mild water based cleaner or soap and water Do not use hydrocarbon based cleaners Do not place items on the vinyl enclosure Do not subject the vinyl enclosure to sharp or abrasive objects Be...

Page 17: ...eceptacles for general use 1 ea receptacle controlled by remove variable speed knob All receptacles rated 15 A entire circuit rated 15 A Scrubber speed control Remote variable speed control knob locat...

Page 18: ...the purchase price of such goods AT will pay return transportation charges on returned goods not exceeding the transportation charges applicable to shipment from original destination unless the return...

Page 19: ...18 EXTENSION LADDER WARNING AND INSTRUCTION LABELS...

Page 20: ...19 AG8000 WIRING DIAGRAM Starting Serial Number C800019402727...

Reviews: