Abatement Technologies AIRE GUARDIAN AG8000 Instruction Manual Download Page 18

17 

 

CERTIFICATION OF MOBILE CONTAINMENT UNITS 

Abatement  Technologies  AG8000  mobile  containment  control  panels 
are  independently  tested  and  certified  to  the  relevant  safety 
requirements by TÜV SÜD. 
 
TÜV  SÜD  is  accredited  by  the  U.S.  Occupational  Safety  and  Health 
Administration (OSHA) as a Nationally Recognized Testing Laboratory 
(NRTL). 

 

LIMITED WARRANTY 

Abatement Technologies (AT) warrants that goods sold to the original user shall be free 
from  defects  in  material  and  workmanship  for  a  period  of  1  year,  except  such  as  are 
commercially acceptable. 

AT does not warrant that the goods sold are merchantable 

or fit for any particular purpose.  AT makes no warranties other than as stated in 
this  paragraph.  All  other  warranties,  guaranties,  or  representations,  express  or 
implied, by operation of law or otherwise, are expressly disclaimed. 

Goods found by 

AT  to  be  defective  or  not  to  conform  to  specification  shall  upon  return  be  replaced  or 
repaired  by  AT  without  any  additional  charges,  or,  at  AT

’s  option,  AT  may  refund  the 

purchase  price  of  such  goods.  AT  will  pay  return  transportation  charges  on  returned 
goods  not  exceeding  the  transportation  charges  applicable  to  shipment  from  original 
destination unless the returned goods are free from defect and conform to specifications. 
Returned  goods  which  are  found  by  AT  to  be  free  from  defect  and  to  conform  to 
specifications  shall  be  held  for  Purchaser’s  shipping  instructions,  which  instructions 
Purchaser shall furnish promptly upon request. 

AT

’s liability shall in no event extend 

beyond  replacement,  repair  or  refund  of  the  purchase  price  and  AT  shall  not  be 
liable under any circumstances for special, contingent or consequential damages, 
nor for loss, damages, or expenses directly or indirectly arising from the use of the 
goods,  including  without  limitation,  warehousing,  labor,  handling  and  service 
charges, die, equipment, or machine breakage, nor for costs, lost profits or loss of 
good  will.  The  use  of  substitute,  non-AT  parts,  in  any  AT  product,  voids  all 
warranties and performance claims. The remedies set forth herein are exclusive

 
For  warranty  information  and  assistance  contact  Abatement  Technologies’  Customer 
Service Department at +1 800 634 9091 (U.S.) or +1 905 871 4720 (Canada). 

 

 

Summary of Contents for AIRE GUARDIAN AG8000

Page 1: ...UCTION MANUAL Covered by one of more of the following U S Patent No 9 574 399 U S Patent No 10 195 979 Canada Patent No 2 895 016 Abatement Technologies Abatement Technologies Inc Georgia USA 1 800 63...

Page 2: ...echnologies at 1 800 634 9091 US or 1 905 871 4720 Canada for assistance or to request a digital copy of this manual Table of Contents Important Safety Instructions 1 General Information 3 Transportin...

Page 3: ...ways check to be certain no one is inside the unit before moving it Use only on level dry surfaces Do not use on slippery surfaces Do not put anything under the base or wheels of the AIRE GUARDIAN AG8...

Page 4: ...AG8000 is designed to be used with the provided extension ladder only and should not be used with any other ladder Read all instructions within this manual as well as all danger caution and instructi...

Page 5: ...items such as pipe or conduit D Handles A total of 8 handles are located at the corners of the mobile containment cart to assist in transport E Fiberglass extension ladder The AIRE GUARDIAN AG8000 was...

Page 6: ...luded K External receptacles The unit comes with a 3 prong male receptacle for connection to a 120V 60Hz power source that is used to power the female receptacles on the unit There is also a receptacl...

Page 7: ...with the remote variable speed knob that can be accessed while standing on the extension ladder R Internal GFCI receptacles One receptacle is designated for a PAS750 Portable Air Scrubber to allow re...

Page 8: ...access projects P N AG8000 SA Once installed the Side Access Panel and the original clear polycarbonate panel are interchangeable An optional Extension can be purchased to reach ceiling heights of 12...

Page 9: ...elp prevent over extending the header into the ceiling use the lowest clutch setting that is able to raise the header to the ceiling Turn hand crank clockwise to raise the header Turn hand crank count...

Page 10: ...nto the POWER SUPPLY outlet located on the back side of the unit and the male end into a 110V 120V 60Hz single phase outlet The AG8000 comes equipped with a power cord wrap that is located below the P...

Page 11: ...nd to maintain the minimum 75 angle required per OSHA requirements Opening and closing the top cover The top cover has a zipper down each long side and is secured by hook and loop on the short side ne...

Page 12: ...20VAC VARIABLE SPEED DEVICE ONLY as shown in the picture above If the PAS750 or PRED750 unit is located external to the AG8000 ensure it is plugged into the outlet labeled FOR 120VAC VARIABLE SPEED DE...

Page 13: ...n still be moved without crashing into any objects After raising the header close to the ceiling fine tune the positioning by aligning the arrow marker closest to the back of the unit with the ceiling...

Page 14: ...tor Locate the pressure monitor mounting bracket on the inside back wall of the AG8000 Remove the faceplate from the RPM series pressure monitor by unscrewing the two small screws on the sides of the...

Page 15: ...rovided hand crank or a power drill within a few inches of the ceiling Warning Be sure that the upper header will not crash into any device installed in the ceiling such as sprinkler heads sensors etc...

Page 16: ...ean with a mild water based cleaner or soap and water Do not use hydrocarbon based cleaners Do not place items on the vinyl enclosure Do not subject the vinyl enclosure to sharp or abrasive objects Be...

Page 17: ...eceptacles for general use 1 ea receptacle controlled by remove variable speed knob All receptacles rated 15 A entire circuit rated 15 A Scrubber speed control Remote variable speed control knob locat...

Page 18: ...the purchase price of such goods AT will pay return transportation charges on returned goods not exceeding the transportation charges applicable to shipment from original destination unless the return...

Page 19: ...18 EXTENSION LADDER WARNING AND INSTRUCTION LABELS...

Page 20: ...19 AG8000 WIRING DIAGRAM Starting Serial Number C800019402727...

Reviews: