6 VMICPCI-7055/CPCI-7055RC Hardware Reference Manual 

Publication No. 500-657055-000 Rev. G

Compliance Information

This chapter provides the applicable information regarding regulatory 
compliance for the VMICPCI-7055/CPCI-7055RC.

Abaco’s VMICPCI-7055/CPCI-7055RC has been evaluated to and has met the 
requirements for compliance to the following standards:

International Compliance

• EN55022:1998/CISPR 22:1997

• IEC61000-4-2

• IEC61000-4-3

• IEC61000-4-4

• IEC61000-4-5

• IEC61000-4-6

European Union (CE Mark)

• BS EN55024 (1998 w A1:01 & A2: 03)

• BS EN55022 (Class A)

United States

• FCC Part 15, Subpart B, Section 109, Class A

Australia/New Zealand

• AS/NZS CISPR 22 (2002) Class A

Canada

• ICES-003 Class A

FCC Part 15

This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that
may cause undesired operation.

FCC Class A

NOTE

This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with 

the instruction manual, may cause harmful interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

CAUTION

Changes or modifications not expressly approved by the party responsible for compliance could void 

Summary of Contents for VMICPCI-7055

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...7055 CPCI 7055RC PowerPC Based CompactPCI Single Board Computer THE CPCI 7055RC IS DESIGNED TO MEET THE EUROPEAN UNION EU RESTRICTIONS OF HAZARDOUS SUBSTANCE RoHS DIRECTIVE 2015 863 CURRENT REVISION P...

Page 3: ...registered with an approved Producer Compliance Scheme PCS and subject to suitable contractual arrangements being in place will ensure WEEE is processed in accordance with the requirements of the WEE...

Page 4: ...D subscript and binary numbers have a b subscript The prefix 0x shows a hexadecimal number following the C programming language convention Thus One dozen 12D 0x0C 1100b The multipliers k M and G have...

Page 5: ...ttps www abaco com Abaco Documents This document is distributed via the Abaco website You may register for access to manuals via the website LINK https www abaco com download cpci 7055cpci 7055rc hard...

Page 6: ...n the Technical Support database and allocate it a unique Case number for use in any future correspondence Alternatively you may also contact Abaco s Technical Support via LINK support abaco com Retur...

Page 7: ...ollowing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Class A N...

Page 8: ...rity to operate the equipment Canadian Regulations The VMICPCI 7055 CPCI 7055RC Class A digital apparatus complies with Canadian ICES 003 NOTE Any equipment tested and found compliant with FCC Part 15...

Page 9: ...S1 23 1 6 Installation 24 1 7 Installing PMCs 25 1 7 1 PMC Site VIO 25 1 8 Front Rear Panel Connectors 28 1 9 LED Definition 29 1 10 RS232 Serial Port COM0 30 1 11 Using the Serial Port Debug 33 2 Sta...

Page 10: ...Cold Reset 52 B 1 3 Warm Reset 52 B 1 4 Get Self Test Results 53 B 1 5 Set ACPI Power State 54 B 1 6 Get ACPI Power State 55 B 1 7 Get Device GUID command 56 B 1 8 Broadcast Get Device ID 57 B 1 9 Ma...

Page 11: ...PMC 2 J21 Connector Pinout 46 Table A 8 PMC 1 J12 and PMC 2 J22 Connector Pinout 47 Table A 9 PMC 1 J13 Connector Pinout 48 Table A 10 PMC 1 J13 Connector Pinout 49 Table A 11 PMC 1 J14 Connector Pin...

Page 12: ...5 Installing a PMC on the VMICPCI 7055 CPCI 7055RC 26 Figure 1 6 VMICPCI 7055 CPCI 7055RC PMC Backside Mounting 27 Figure 1 7 Front Panel LED Definitions 29 Figure 1 8 Serial Port Access Using Exampl...

Page 13: ...COM2 via CompactPCI J3 Real Time clock calendar Front panel reset switch The Marvell chipset allows the VMICPCI 7055 CPCI 7055RC to provide enhanced features such as Ultra DMA IDE support The standard...

Page 14: ...To cast out or to reload a 256 bit cache line required four access cycles On the 750GX this bus has been expanded to 256 bits As a result cache line data bursts can be read from or written to the cach...

Page 15: ...r fabric supports non blocking concurrent connections among peripherals at full bus speeds delivering break through performance for advanced Internet infrastructure equipment The Discovery III system...

Page 16: ...Bridge 33 MHz Dual ATA 100 CompactFlash Socket 512 Kbyte Flash PLCC32 64 Mbyte Flash RTC 32 Kbyte NVRAM 10 100 1000 LAN Gbit PHY Two Single or One Double Wide PMC Site PMC Site 1 I O 64 bit Device Bus...

Page 17: ...U S 503 797 4207 International 503 234 6762 FAX PCI 6150 PCI to PCI Bridge Chip IDE PLX Technology Inc 870 Maude Ave Sunnyvale CA 94085 USA Tel 1 800 759 3735 Tel 1 408 774 9060 Fax 1 408 774 2169 Ema...

Page 18: ...d MA 01880 617 224 1100 617 224 1239 FAX www picmg org Packet Switching Backplane Specification PICMG 2 16 R1 0 PCI Industrial Computer Manufacturers Group 301 Edgewater Place Suite 220 Wakefield MA 0...

Page 19: ...g boards 1 3 Hardware Setup The VMICPCI 7055 CPCI 7055RC are factory populated with user specified options as part of the VMICPCI 7055 CPCI 7055RC ordering information The RAM size is not user upgrada...

Page 20: ...G Handling and Installation 19 Figure 1 1 VMICPCI 7055 CPCI 7055RC PMC Sites and Jumper Locations J2 J1 J3 J22 J21 J13 J14 J5 J11 J12 E16 J29 J28 J23 U2 D82 S2 D90 D89 E192 1 E252 1 E18 2 1 20 19 S1 K...

Page 21: ...ystem controller will only be accepted until the boot done LED is turned off Table 1 1 Board Connectors Headers Switches and Jumpers Connectors Header Jumpers and Switches Function J1 J2 J3 and J5 Com...

Page 22: ...The location of both headers is shown in the diagram on the following page It will be required for the user to access both headers E5 and E18 in order to utilize the COP interface To use the COP port...

Page 23: ...22 VMICPCI 7055 CPCI 7055RC Hardware Reference Manual Publication No 500 657055 000 Rev G E18 JTAG Header E5 COP Header...

Page 24: ...Positions Pin Position Function 1 On Boot from solder down Flash 64 Mbyte Off Boot from PLCC32 2 On Write protect all NVRAM and I2C bus Off No write protection for NVRAM on I2C bus 3 On Write protect...

Page 25: ...on and setup 2 The VMICPCI 7055 CPCI 7055RC must be installed in a designated slot of the CompactPCI backplane see symbols above for selection of the correct slot NOTE Air flow as measured at the outp...

Page 26: ...devices can easily drive TTL signaling Higher speed PCI buses utilize 3 V termination Figure 1 4 Keypin Installation and Setup CAUTION When Installing the keypins on the two PMC sites the two keypins...

Page 27: ...on the VMICPCI 7055 CPCI 7055RC CAUTION When installing the keypins on the two PMC sites the two keypins MUST be installed for the same voltage level i e either in the 5 V position or in the 3 3 V po...

Page 28: ...Publication No 500 657055 000 Rev G Handling and Installation 27 Figure 1 6 VMICPCI 7055 CPCI 7055RC PMC Backside Mounting Back of VMICPCI 7055 CPCI 7055RC SBC Solder Side...

Page 29: ...5RC provide rear I O support for the following COM1 COM2 PMC I O for one expansion site and IDE These signals are accessed using the VMIACC 7055 ACC 7055RC RTMs which terminate into industry standard...

Page 30: ...low LED Activity Green LED Link Indicates Link Speed LED off indicates 10Base T Yellow LED indicates 100Base TX Green LED indicates 1000Base T LAN0 Yellow LED Indicates the Ethernet is active When LED...

Page 31: ...e terminal with a Windows based OS go to Accessories then to Hyperterminal and click on Hyperterminal When using a Linux based OS go to the root directory at the command prompt and type in Minicom Fig...

Page 32: ...Publication No 500 657055 000 Rev G Handling and Installation 31 Figure 1 9 Hyperterminal New Connection Window 2 Select the COM port you will be using After selecting the COM port click OK...

Page 33: ...ndow will appear Select the Baud rate bits per second The default Baud rate for the VMICPCI 7055 CPCI 7055RC is 9600 Click OK Figure 1 11 COM1 Properties Window Bits per second 9600 Data bits 8 Parity...

Page 34: ...l port See Figure 1 12 below for an example of connecting the VMICPCI 7055 CPCI 7055RC with a PC using the RS232 serial port and cable Figure 1 12 VMICPCI 7055 CPCI 7055RC Serial Port Connection NOTE...

Page 35: ...the standard features of the VMICPCI 7055 CPCI 7055RC 2 1 CPU The VMICPCI 7055 CPCI 7055RC CPU is factory populated with an IBM PowerPC processor The processor speed and Memory CompactFlash size are...

Page 36: ...The primary channel is routed to an optional onboard CompactFlash socket The secondary channel is routed out of the CompactPCI J5 backplane connector to an optional RTM that terminates into a standar...

Page 37: ...based on a 100BaseTX standard uses unshielded twisted pair cables and an RJ45 connector 100BaseTX has a maximum length of 100 meters 2 5 3 1000BaseT The VMICPCI 7055 CPCI 7055RC support 1000BaseT usin...

Page 38: ...eripheral controller it allows the local VMICPCI 7055 CPCI 7055RC processors to configure and control the onboard local subsystem independent from the CompactPCI bus host processor The VMICPCI 7055 CP...

Page 39: ...nd the CompactPCI J3 are option dependent Contact Sales for ordering information NOTE The system backplane must support the PICMG 2 16 specification and a PICMG 2 16 compatible switch is required for...

Page 40: ...unce and reliable operation in noisy environments The key prevents misalignment of the board when installing in the chassis Figure below depicts the J1 connector and the connector pinout Table A 1 J1...

Page 41: ...CPCI_AD 2 5 CPCI_AD 2 4 GND 7 CPCI_AD 30 CPCI_AD 29 CPCI_AD 28 GND CPCI_AD 2 7 GND 6 CPCI_REQ CPCI_PCI_PRES ENT CPCI_3V_C6 CPCI_CLK CPCI_AD 3 1 GND 5 N C N C CPCI_RST GND CPCI_GNT GND 4 CPCI_IPMB_P W...

Page 42: ...D 18 N C N C N C GND N C GND 17 N C GND BP_RST CPCI_REQ6 CPCI_GNT6 GND 16 N C N C CPCI_DEG GND N C GND 15 N C GND CPCI_FAL CPCI_REQ5 CPCI_GNT5 GND 14 CPCI_AD 3 5 CPCI_AD 3 4 CPCI_AD 33 GND CPCI_AD 32...

Page 43: ...t Pin No Row A Row B Row C Row D Row E Row F 19 GND GND GND GND GND GND 18 LPA_BI_DA LPA_BI_DA 2 GND LPA_BI_DC LPA_BI_DC GND 17 LPA_BI_DB LPA_BI_DB 2 GND LPA_BI_DD LPA_BI_DD GND 16 LPB_BI_DA LPB_BI_DA...

Page 44: ...es the J5 connector and the connector pinout 1 N C N C N C G2_G_LINK10 G2_Y_ACT GND Table A 3 J3 Connector and Pinout Pin No Row A Row B Row C Row D Row E Row F Table A 4 J5 Connector and Pinout Pin N...

Page 45: ...E_D 9 IDE_CS1 IDE_D 1 VCC_5 0 GND 6 IDE_DIOW IDE_D 10 HD_ACTA IDE_D 2 N C GND 5 UDMA_Sec_DE TECT IDE_D 11 IDE_CS3 IDE_D 3 GND GND 4 IDE_CBLIO IDE_D 12 IDE_INTRQ IDE_D 7 N C GND 3 N C IDE_D 13 IDE_DMAC...

Page 46: ...re A 2 Serial Connector and Pinout NOTE An RJ45 to DB9 adapter cable Part Number 360 010030 002 non RoHS or 42G7602 0002 RoHS is shipped with the VMICPCI 7055 CPCI 7055RC The RJ45 pinout supports asyn...

Page 47: ...1 J21 PMC Connector J11 J21 Left Side Right Side Left Side Right Side Pin Name Pin Name Pin Name Pin Name 1 GND 2 12 V 33 FRAME 34 GND 3 GND 4 INTA 35 GND 36 IRDY 5 INTB 6 INTC 37 DEVSEL 38 5 0 V 7 PM...

Page 48: ...x_VIO 33 GND 34 N C 3 GND 4 N C 35 TRDY 36 3 3 V 5 Px_VIO 6 GND 37 GND 38 STOP 7 GND 8 N C 39 PERR 40 GND 9 N C 10 N C 41 3 3 V 42 SERR 11 BMODE2 12 3 3 V 43 C BE 1 44 GND 13 RESET 14 GND 45 AD 14 46...

Page 49: ...33 GND 34 AD 48 3 GND 4 C BE 7 35 AD 47 36 AD 46 5 C BE 6 6 C BE 5 37 AD 45 38 GND 7 C BE 4 8 GND 39 VIO 40 AD 44 9 VIO 10 PAR64 41 AD 43 42 AD 42 11 AD 63 12 AD 62 43 AD 41 44 GND 13 AD 61 14 GND 45...

Page 50: ...8 3 GND 4 C BE 7 35 AD 47 36 AD 46 5 C BE 6 6 C BE 5 37 AD 45 38 GND 7 C BE 4 8 GND 39 VIO 40 AD 44 9 VIO 10 PAR64 41 AD 43 42 AD 42 11 AD 63 12 AD 62 43 AD 41 44 GND 13 AD 61 14 GND 45 GND 46 AD 40 1...

Page 51: ...IO 9 10 PMC1_IO 1 0 41 PMC1_IO 4 1 42 PMC1_IO 42 11 PMC1_IO 1 1 12 PMC1_IO 1 2 43 PMC1_IO 4 3 44 PMC1_IO 44 13 PMC1_IO 1 3 14 PMC1_IO 1 4 45 PMC1_IO 4 5 46 PMC1_IO 46 15 PMC1_IO 1 5 16 PMC1_IO 1 6 47...

Page 52: ...ands B 1 1 Get Device ID This command is used to retrieve the Intelligent device s Hardware Revision Firmware Software Revision and Sensor and Event Interface Command specification revision informatio...

Page 53: ...hreshold values and other power up default states to be restored Table B 2 NetFn 0x06 Cmd 0x02 B 1 3 Warm Reset While there are two commands one for a cold reset and one for a warm reset the firmware...

Page 54: ...orrupted or inaccessible data or devices Fatal hardware error Reserved Device specific internal failure 3 XXh If byte 2 is 55h 56h or FFh then 00h If byte 2 is 58h or All other then device specific If...

Page 55: ...ower state instead it can be used to turn off on power to the board Table B 5 NetFn 0x06 Cmd 0x06 Byte Value Data Field Comments Request data 1 XXh ACPI System power state The Abaco IPMI does not have...

Page 56: ...rns whether the board has its power turned off on Table B 6 NetFn 0x06 Cmd 0x07 Byte Value Data Field Comments Request data Response data 1 00 Completion code 2 2Ah ACPI System Power State 7 reserved...

Page 57: ...gement controller This information can be used in conjunction with the SDR information to verify that a particular controller is still present in the system Table B 7 NetFn 0x06 Cmd 0x08 Byte Value Da...

Page 58: ...d accesses to the IPMB or private buses behind the management controller Table B 8 NetFn 0x06 Cmd 0x52 Byt e Value Data Field Comments Request data 1 XXh Bus ID 7 4 channel number 3 1 bus ID 0 based 0...

Page 59: ...1 11 Get Event Receiver This command gets the current setting for the Event Receiver slave address and LUN Table B 10 NetFn 0x04 Cmd 0x01 Byte Value Data Field Comments Request data 1 XXh Event Recei...

Page 60: ...n the Sensor Data Records Byte Value Data Field Comments Request data 1 XXh Sensor Number FFh reserved Response data 1 00h Completion code 2 XXh Sensor reading 3 XXh 7 0b All event messages disabled f...

Page 61: ...nsor 0x44 says 0xC3 195 decimal the actual voltage is 195 256 3 3 2 5 027 V c For Temp sensors Ta Tr Where Ta actual temperature in o C Tr raw sensor reading e g if sensor 0x61 says 0x1f 31 decimal th...

Page 62: ...g of the FRU data is performed by the IPMI subsystem system management software is responsible for creating valid FRU data structures and writing the data to the FRU area Table B 14 NetFn 0x0A Cmd 0x1...

Page 63: ...Byte Value Data Field Comments Request data Response data 1 00h Completion code 2 51h SDR Version 3 XXh Record count LS Byte 4 XXh Record count MS Byte 5 6 XXXXh Free space in bytes LS Byte first 000h...

Page 64: ...the repository FFFFh specifies that the last SDR in the repository should be listed If Record ID is non zero the command returns the information from the matching record and the Record ID for the next...

Page 65: ...6D 62 65 64 64 65 64 Abaco 0020 20 53 79 73 74 65 6D 73 CC 56 4D 49 43 50 43 49 Systems CPCI 0030 2D 37 38 30 36 C5 31 30 30 30 31 CE 33 35 30 2D 7055 10001 350 0040 36 35 37 38 30 36 2D 32 31 30 C0 C...

Page 66: ...nt of an Event Request Message For IPMB messages this field is equated to the Requestor s Slave Address and LUN fields Thus the Generator ID information is not carried in the data field of an IPMB req...

Page 67: ...certain CompactPCI signals These functions are controlled by sending IPMI packets from the VMICPCI 7055 CPCI 7055RC processor cards to the controller B 4 1 Get Geographical Address This command retur...

Page 68: ...ve it sent back to the VMICPCI 7055 CPCI 7055RC If the request cannot be relayed due to a device not responding or the Zircon is temporarily out of memory the response to this command will use the Net...

Page 69: ...d Table B 21 NetFn 0x32 Cmd 0x80 If the forwarding address is 0 by default or deliberately set events will not be forwarded In all cases any Platform Events will be acknowledged back to the original s...

Page 70: ...ED AS IS WITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LI...