background image

Standard controller  –

 

Installation manual 

 

6

 

                                                                    AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.

 

                                                             All rights reserved.

 

 

 

4. KDH

-

KS3024

-

IP controller module

 

Communication 

port for 

 

software

 

 

 

RS485 port for 

extension 

 

module

 

 

Door contact 

door 4

 

Door contact 

door 3

 

Door contact 

door 2

 

Door contact 

door 1

 

 

Relay output

 

RL5

 

 

 

Relay output

 

RL4

 

 

 

Relay output

 

RL3

 

 

 

Relay output

 

RL2

 

 

 

Relay output

 

RL1

 

 

Power supply

 

12 VDC

 

 

 

Reader port

 

RDR 1

 

 

 

 

 

 

Reader port

 

RDR 2

 

 

 

Reader port

 

RDR 3

 

 

 

 

 

Reader port

 

RDR 4

 

 

Exit button 

door 1

 

Exit button 

door 2

 

Exit button 

door 3

 

Exit button 

door 4

 

Alarm input 1

 

 

Alarm input 2

 

 

Alarm input 3

 

 

Alarm input 4

 

Enable mode for card adding 

 

without software

 

Communication password

 

reset

 

Control output for additional indicators

 

LED: POWER & RUN on enclosure cover (option)

 

Controller operating indicator

 

 

 

 

Card reading indicator

 

 

 

 

Two door control mode indicator

 

Relay X switch indicator

 

 

 

 

 

+12 VDC power supply indicator

 

4 DOOR

 

Summary of Contents for KaDe KDH-KS3012-IP

Page 1: ...EADER KDH C130U BLACK KDH C130M BLACK KDH CK130U BLACK KDH CK130M BLACK WERSION 2 0 28 11 2018 Installation Manual PROXIMITY CARD READER KDH C130U BLACK KDH C130M BLACK KDH CK130U BLACK KDH CK130M BLA...

Page 2: ...idelines for controller installation 5 4 KDH KS3024 IP controller module 6 5 Reader exit button and sensor connection 7 6 Power supply lock Ethernet door sensor and I O module connection 8 7 APSAAT4 p...

Page 3: ...trollers are also provided with additional RS485 port in order to connect extension module MOD2000INOUT List of the most important controller features and parameters is presented in attached table Sys...

Page 4: ...CP Extension modules connection RS485 dedicated port Readers cards readers ports 4 ports Wiegand interface card formats 26 34 bit Wiegand self defined card types Compatible with reader technology keyp...

Page 5: ...edicated power supply type APSAAT4 described in further part of manual Wire connections and works with internal controller parts with power on is strictly prohibited as it may damage the device Before...

Page 6: ...Relay output RL1 Power supply 12 VDC Reader port RDR 1 Reader port RDR 2 Reader port RDR 3 Reader port RDR 4 Exit button door 1 Exit button door 2 Exit button door 3 Exit button door 4 Alarm input 1 A...

Page 7: ...YELLOW OUT BUZ1 MOD YELLOW OUT BUZ2 MOD GREEN WHITE BROWN BLACK RED GREEN WHITE BROWN READER D3 READER D4 YELLOW OUT BUZ3 MOD YELLOW OUT BUZ4 MOD BUTTON D2 ALARM LINE 1 ALARM LINE 2 ALARM LINE 3 ALAR...

Page 8: ...ore modules with different addresses to one controller PSU 12VDC Integrated in APSAAT4 Lock NC type lock Lock NO type lock Alarm siren I O module Switch TCP RS485 A RS485 B RS485 GND 1 C 1 NC 1 N0 1 A...

Page 9: ...uts relay and transistor with LED indication EPS technical output for absence of AC supply PSU output signalling absence of DC voltage power supply failure LoB output signalling low battery voltage Ab...

Page 10: ...t AUX 1 12VDC with controller terminals additional terminals on controller module supply socket can be connected to I O module according to figure on previous page connect controller RS485 port using...

Page 11: ...h controller Procedure for creating programming card 1 Push the button Mode located on the upper edge of controller and hold it for 3 seconds Read any card in the reader it will be programming card To...

Page 12: ......

Reviews: