background image

   

 

 

 

 

Standard controller  –

 

Installation manual 

 

AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.

 

                     All rights reserved.

 

3

 

 

 

1. Introduction

 

 

 

KDH

-

KS3024

-

IP

 series standard controller is designed to be used in access 

control system, managed by 

NMS  ACCESS  CONTROL 

software. Standard con-

trollers (unlike integrated controllers) are made in the form of modules, placed in 

metal enclosure with power supply. They are located in the protected area. Other 

system  components  (readers,  electric  locks,  buttons)  are  installed  next  to  the 

controlled door and connected to the controller. Such solution guarantees higher 

system security  level, compared to integrated controllers. Readers can use any 

identification technology, provided they adopt Wiegand 26

-

40 bit interface.

 

 

 

KDH

-

KS3024

-

IP model can handle:

 

• 

2 door 

-

 two way 

 

• 

4 doors 

-

 one way

 

 

 

Models  KDH

-

KS3012/24

-

IP  have  built

-

in  IP  ports  for  communication  with 

NMS  ACCESS  CONTROL  software.  Controllers  are  also  provided  with  additional 

RS485 port, in order to connect extension module MOD2000INOUT.

 

 

 

List of the most  important controller features and parameters is presented 

in attached table.

 

 

 

 

System capacity depends on software licence. Free version supports up to 8 

controllers. To increase number of supported devices, proper licence purchase is 

needed. 

 

 

 

It is possible to store up to 20000 cards in controller memory.

 

 

For  each  controller  it  is  possible  to  connect  KDH

-

MOD2000INOUT  module, 

equipped  with  4  relay  outputs,  4  inputs  and  4  transistor  outputs,  controlling 

buzzers in readers.

 

 

 

3000 series standard controllers, compatible with

 

NMS ACCESS CONTROL software.

 

Symbol

 

Controller description

 

KDH

-

KS3012

-

IP

 

Standard controller, 1 door 

-

 two way, 2 doors 

-

 one way, 2 readers ports, TCP port for 

communication and RS485 port for extension module, buffer for 20 000 cards, 50 000 

events, 20 000 alarms 

 

 

KDH

-

KS3024

-

IP

 

Standard controller, 2 door 

-

 two way, 4 doors 

-

 one way, 4 readers ports, TCP port for 

communication and RS485 port for extension module, buffer for 20 000 cards, 50 000 

events, 20 000 alarms 

 

 

Summary of Contents for KaDe KDH-KS3012-IP

Page 1: ...EADER KDH C130U BLACK KDH C130M BLACK KDH CK130U BLACK KDH CK130M BLACK WERSION 2 0 28 11 2018 Installation Manual PROXIMITY CARD READER KDH C130U BLACK KDH C130M BLACK KDH CK130U BLACK KDH CK130M BLA...

Page 2: ...idelines for controller installation 5 4 KDH KS3024 IP controller module 6 5 Reader exit button and sensor connection 7 6 Power supply lock Ethernet door sensor and I O module connection 8 7 APSAAT4 p...

Page 3: ...trollers are also provided with additional RS485 port in order to connect extension module MOD2000INOUT List of the most important controller features and parameters is presented in attached table Sys...

Page 4: ...CP Extension modules connection RS485 dedicated port Readers cards readers ports 4 ports Wiegand interface card formats 26 34 bit Wiegand self defined card types Compatible with reader technology keyp...

Page 5: ...edicated power supply type APSAAT4 described in further part of manual Wire connections and works with internal controller parts with power on is strictly prohibited as it may damage the device Before...

Page 6: ...Relay output RL1 Power supply 12 VDC Reader port RDR 1 Reader port RDR 2 Reader port RDR 3 Reader port RDR 4 Exit button door 1 Exit button door 2 Exit button door 3 Exit button door 4 Alarm input 1 A...

Page 7: ...YELLOW OUT BUZ1 MOD YELLOW OUT BUZ2 MOD GREEN WHITE BROWN BLACK RED GREEN WHITE BROWN READER D3 READER D4 YELLOW OUT BUZ3 MOD YELLOW OUT BUZ4 MOD BUTTON D2 ALARM LINE 1 ALARM LINE 2 ALARM LINE 3 ALAR...

Page 8: ...ore modules with different addresses to one controller PSU 12VDC Integrated in APSAAT4 Lock NC type lock Lock NO type lock Alarm siren I O module Switch TCP RS485 A RS485 B RS485 GND 1 C 1 NC 1 N0 1 A...

Page 9: ...uts relay and transistor with LED indication EPS technical output for absence of AC supply PSU output signalling absence of DC voltage power supply failure LoB output signalling low battery voltage Ab...

Page 10: ...t AUX 1 12VDC with controller terminals additional terminals on controller module supply socket can be connected to I O module according to figure on previous page connect controller RS485 port using...

Page 11: ...h controller Procedure for creating programming card 1 Push the button Mode located on the upper edge of controller and hold it for 3 seconds Read any card in the reader it will be programming card To...

Page 12: ......

Reviews: