Integrated Access Controller – Installation manual
All rights reserved. © AAT HOLDING S.A.
5
Wiring diagram
Wire Color
Function
Notes
Basic Standalone Wiring
Red
AC & DC
AC/DC Power input, +12V DC Power Input
Grey & Black
AC & DC
AC/DC Power input
Black
GND
Negative Pole of DC Power Input
Blue
Relay NO
Normally Open Relay Output (install diode provided)
White & Black Relay Common
Common Connection for Relay Output
Green & Black
Relay NC
Normally Closed Relay Output (Install diode provided)
Yellow
OPEN
Request to Exit (REX) Input or BUZZER
Pass-Through Wiring (Wiegand or Controller)
Green
Data 0
Wiegand Output (Pass-through) Data 0
White
Data 1
Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey
Alarm Output
Negative contact for Alarm
Brown
Contact Input
Door/Gate Contact Input (Normally Closed) or LED
Brown & Black Door Bell
Door bell control
Yellow & Black Door Bell
Door bell control
Sound and Light Indication
Operation Status
LED
Buzzer
Stand by
Red light bright
-
Enter into programming mode
Red light shines
One beep
In the programming mode
Orange light bright
One beep
Operation error
-
Three beeps
Exit from the programming
mode
Red light bright
One beep
Open lock
Green light bright
One beep
Alarm
Red light Shines quickly
Beeps
Basic Configure
Please use the keypad to program controller.
Enter and Exit Program mode
Programming Step
Keystroke Combination
Enter Program Mode
*
(Master Code) #
(Factory default is 123456)
Exit Program Mode
*