Integrated Access Controller – Installation manual
All rights reserved. © AAT HOLDING S.A.
8
Delete Users
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Set Access Mode
Programming Step
Keystroke Combination
1. Enter Program Mode
﹡
(Master Code) #
Delete Card User - Common
2. Delete Card - By Card
OR
2. Delete Card - By ID number
OR
2. Delete User - By Card number
2 (Read Card) #
The cards can be deleted continuously.
2 (User ID ) #
2 (Input 8/10 digits Card number) #
Delete PIN User - Common
2. Delete PIN – by PIN
OR
2. Delete PIN – By ID number
2 (Input PIN) #
2 (User ID ) #
Delete Panic User
2. Delete Panic Card User
OR
2. Delete Panic PIN User
2 (User ID ) #
2 (User ID ) #
Delete All Users
Delete All User
2 (Master Code) #
3. Exit
﹡
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Pulse Mode
OR
2. Toggle Mode
3 (1-99) #
(factory default)
The relay time is 1-99 seconds. (1 is 50mS.)
(Default is 5 seconds)
3 0 #
Sets the relay to ON/OFF Toggle mode
3. Exit
*
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Card access
OR
2. Card + PIN access
OR
2. Card or PIN access
OR
2. Multi-Cards (or PINs) access
4 0 #
4 1 #
4 2 #
4 3 (2~9) #
(Only after reading 2~9 cards or inputting 2~9 PINs,
the door can be opened)
3. Exit
*