58
Aastra MBU 400 Administrator Guide
Using Configuration Files
Configuration file example:
European (CET) configuration for DST start last Sunday in March, and DST end on
last Sunday in October.
Logging
The gateway logs information continuously to an internal log buffer. This log can be
viewed using the internal Aastra Web UI, or the gateway can be configured to
automatically upload log files to the boot server.
The configuration parameter VOIP_LOG_AUTO_UPLOAD can be used to control
automatic uploading of log files. Log files are named <MAC-
addr>_<MMDDHHMMSS>(b).log. The first log file is marked with a 'b' indicating
that it is a boot log, and the time in the filename is given in GMT regardless of the
timezone setting.
If using TFTP, the boot server must contain a directory named 'log' in the root folder,
whereas using HTTP, the MANAGEMENT_UPLOAD_SCRIPT parameter
(indicating the configuration file directory) is used to configure a script to handle file
uploads.
DST_STOP_DATE
1..31
DST start date.
Not used if FixedDayEnable is set to
FALSE (default=1)
DST_STOP_TIME
0…23
DST start time. (Default=2)
DST_STOP_DAY_OF_WEEK
1..7 (1=Sunday)
(Default = 1)
DST_STOP_WDAY_LAST_IN_MONTH
0,1,2,3
0: Stop day of week first in month.
1: Stop day of week last in month 2: Start
day of week second first in month.
3: Start day of week second last in
month.
(Default=0)
Parameter (Continued)
Possible values (Continued)
Description (Continued)
%DST_ENABLE%:2
%DST_FIXED_DAY_ENABLE%:00
// Disable
%DST_START_MONTH%:3
// March
%DST_START_DATE%:1
// Dummy value
%DST_START_TIME%:01
// 02.00
%DST_START_DAY_OF_WEEK%:1
// Sunday
%DST_START_WDAY_LAST_IN_MONTH%:1
// start on LAST Sunday.
%DST_STOP_MONTH%:10
// October
%DST_STOP_DATE%:2
// Dummy value
%DST_STOP_TIME%:02
// 02.00
%DST_STOP_DAY_OF_WEEK%:1
// Sunday
%DST_STOP_WDAY_LAST_IN_MONTH%:1
// Stop on LAST Sunday.
Summary of Contents for MBU 400
Page 1: ...Administrator Guide 41 001287 00 Rev 00 MBU 400 MBU 400 TM Release 1 0...
Page 4: ......
Page 12: ......
Page 68: ......
Page 73: ......