Aastra MBU 400 Administrator Guide
47
Using Configuration Files
Updating Firmware
The firmware update process can be initiated from the handset, by sending a SIP
notify with a check-sync event to the gateway, or by scheduling a firmware update.
Handset initiated firmware updates
A firmware update can be initiated from the handset using
Settings
>
System
settings
>
Firmware update
. In the firmware update menu select the desired firmware
version and language. Use the right and left navigation keys to switch between the
Simple
and
Advanced
pages.
Note:
The popup in idle mode announcing new firmware will not be displayed when
the
System settings
menu is pincode protected.
Automatic indication of new firmware
By sending a SIP notify with event check-sync to the management SIP UA the
gateway will update to the newest software available in the firmware update path on
the firmware update server.
The following configuration is needed for firmware update.
Initiating firmware update by schedule
By default the Aastra MBU 400 system searches for a new firmware once every 24
hours (with a random time-offset). If new firmware is found, the handset will prompt
the user for a system update. Firmware updates can be scheduled on the Aastra MBU
400 gateway in the following ways.
• Define a time [HH:MM] for the MBU to search for an update. This will cause the
system to search for new firmware update every day at the specified time.
• Define a polling period; this will cause the MBU to search for new software every
after each specified time interval (or polling period), and if new software is found
to update the system.
Parameter
Possible values
Description
FWU_TFTP_SERVER_PATH
String (max 31 characters)
Firmware update server path in which to
look for firmware update files. The path
may contain multiple directories. The path
must start with a slash and must end with
a slash. Backslashes are not allowed.
NETWORK_FWU_SERVER
String (max 31 characters)
DNS name or IP address of the server
that contains firmware update files.
MANAGEMENT_TRANSFER_PROTOCOL 0: TFTP
1: HTTP (Default)
Selects which protocol to use for firmware
download and configuration file
download.
REQUIRED_FIRMWARE_VERSION
(default is current version
number)
Indicates the required firmware verions
for the Aastra MBU 400 system.