Installation and Setup
8
41-001501-00 REV01 – 08.2013
Rack Mounting
If you choose to mount the BluStar for Conference Room system in a rack, perform the following steps:
Wall Mounting
With wall mounting, there are two possibilities. In the first variant the front panel faces right; in the second, it faces
downwards (refer to
for details). The wall mounting option chosen will depend on the
way the cables are routed. The LED display remains visible whatever the mounting position.
1.
Remove the left and right screw covers from the BluStar for Conference Room system
.
2.
Attach the left and right rack mount adapters using the supplied Torx M4x12 screws with the appropriate Torx screwdriver.
3.
Attach the BluStar for Conference Room system to the standard 2U audio/video component rack system of your choice.
Note:
Optimization of air flow and heat dissipation must be taken into consideration and therefore a wall-mounting option
in which the front panel faces upwards or to the left is not permitted. Inadequate heat dissipation can damage the sys-
tem.
Left and Right Screw Covers