Model
/
Administration Guide 10
Setting Parameters
– Time Server Settings
Setting Parameters – Time Server Settings
The following section contains the parameters to configure settings specific to the
timeserver.
Range
Not Applicable
Example
sip rtp port: 5130
Parameter
–
time server disabled
Configurable through the 480i's Options List or the
configuration files
Description
This parameter enables or disables the time server. This
parameter affects the time server1, time server2 and
time server3 parameters. Use "0" to enable time server
and "1" to disable time server.
Format
Integer
Default Value
0
Range
0 or 1
Example
Time server disabled: 0
Parameter
–
time server1
Configurable through the 480i's Options List or the
configuration files.
Description
The primary time server's IP address. If the time server
is enabled, the value for time server1 will be used to
request the time from.
Format
IP address
Default Value
0.0.0.0
Range
Not Applicable
Example
time server1: 192.168.0.5
Parameter
–
time server2
Configurable through the configuration files only
Description
The secondary time server's IP address. If the time
server is enabled, and the primary time server is not
configured or cannot be accessed the value for time
server2 will be used to request the time from.
Format
IP address
Default Value
0.0.0.0
Range
Not Applicable
Example
time server2: 192.168.0.5