Typical 50mm
Page 27
Aarrow Sherborne GSL CF
INSTALLATION INSTRUCTIONS
Commissioning the stove
Refit the glass/glass frame assembly.
Refit the outer body and secure with locking
levers
If horizontal flue is used fit the canopy cover
plate (See page 30 step 1a)
If top flue is used locate the infill plate (see
pages 30 step 1b)
Follow the lighting instructions (see pages 36
& 37), light the pilot and check:-
1. The operation of the controls
2. The cross lighting of the burner
3. All gas settings can be achieved
Fire testing
Flame failure device testing
Step 1.
Ignite the appliance in accordance
with page 36 and run for 60 seconds.
Step 2.
turn the appliance off to extinguish
the pilot, listen for a snap at the control valve.
This should occur within 60 seconds of the
pilot flame being extinguished. The snap
sound will be the gas valve magnet
disengaging, and thus shutting off the flow of
gas to the pilot and burner.
Spillage Test
Step 1.
Close all doors and windows.
Step2.
Light the appliance and set on to the
high rate
Step3.
Allow the fire to warm up for 10
minutes
Step 4.
Position the smoke match at the
back of the fire centrally beneath the rear
diverter as shown in
Fig 27.
All of the smoke should be drawn into the
fire. If this does not occur the appliance must
be disconnected and the flue checked
Step 5.
If there is an extractor fan in any
room, this must be turned on and any doors
between it and the fire left open, repeat the
spillage test
Fig. 28
Repeated operation of the spillage monitoring
system whereby the OSD (oxygen sensing
device/spillage monitoring system). If there is a
problem with the OSD pilot going out after the
stove has operated satisfactorily , this indicates a
possible flue draw problem. Seek expert advise
from a qualified engineer.
Warning: The spillage monitoring system,
consists of a special sensing device (OSD)
pilot and is a safety feature required by law. It
must not be adjusted or put out of action by
the installer. If the spillage monitoring system
or any of its parts are to be replaced, only use
original manufacturers parts must be used.
Note:
The stove will give off non-toxic fumes
when first used. This is perfectly normal it will
disappear after the first few hours. Once the
spillage test is completed open the doors to
ventilate the area.
Self Levelling Rear Feet
Once the stove is in position on the hearth,
working on the rear legs simply loosen the pozi
screw and rotate the inner „pear‟ shaped adjuster
to touch the hearth. Re-tighten the screw and
repeat for the other side.