IMPORTANT NOTICES
A qualified gas engineer must carry out the
installation and servicing of this appliance in
accordance with these instructions and in
compliance with current Building Regulations.
Such person must be a registered CORGI
engineer.
This appliance is designed to run on natural gas
only.
Warning - Only use the appliance with the
specified gas.
The fire is fitted with a safety device to shut down
the appliance if there is inadequate flue draw. If the
fire shuts down for no apparent reason check
chimney and air inlets to the room. In all cases the
fire must not be re-lit until the safety aspects have
been checked by a qualified gas engineer.
Please note the following;
• The safety device must
never
be put out of
action.
• Sealed components must not be interfered
with.
• Servicing instructions and part identification
numbers are given towards the back of the
manual.
• Only use genuine
Aarrow
parts for
replacements.
• Ventilation, purpose built ventilation is not
normally required for either appliance,
normal adventitious room ventilation being
sufficient.
• Coal Set, see safety notice on page 4.
All surfaces except the control knob, the control
door handle and control door are considered to be
working surfaces.
Warning: Under no circumstances must the fire
be operated if the glass is cracked or broken.
Warning: If it is known or suspected that an
operational or ignition fault exists on the
appliance, it must not be used until it has been
investigated and corrected by a qualified gas
engineer.
Warning:
THIS GAS APPLIANCE MUST BE
SERVICED EVERY TWELVE MONTHS BY A
QUALIFIED GAS ENGINEER.
STATUTORY REQUIREMENTS
The current Gas Safety (Installation and Use)
Regulations (as amended).
The Building Regulations for England and Wales
2000 ref Approved Document J 2002 edition
(issued by the DTLR).
The Building Standards (Scotland) (Consolidation)
Regulations.
Detailed recommendations are outlined in the
current issue of the following British Standards:-
BS5440 parts 1 and 2, BS5871 part 1 and BS6891.
Any Manufacturer's Instructions must not be
taken as overriding statutory requirements.
_________________________________________
CERTIFICATION
This appliance is CE certificated for performance
and safety. Therefore, it is important that no
alteration is made to the appliance.
Any alteration not approved by
Aarrow Fires Ltd.
will invalidate the guarantee.
Becton Bunny & Becton 7 mk3 Gas stoves
5
INTRODUCTION