Examples
Hopper at 03 Value 100
- is a hopper whose value is initialised to 100
Hopper at 03 Readout Value
- is a hopper that is unusable unless a coin value can be
read out, or set by the application.
Hopper at 03
- is a hopper that is unusable unless the application sets a
coin value.
Hopper at 03 Value 100 Azkoyen - is a hopper whose value is initialised to 100 and that will
be unconditionally use the Azkoyen protocol variations.
NOTE ACCEPTOR [IS] ELITE
This must follow a
USB
keyword, and specifies that an Elite note is connected directly to the
PC via a USB lead.
COIN RECYCLER [IS] CR01x | BCS
This must follow a
USB
keyword, and specifies that the corresponding coin recycler system
is connected directly to the PC via a USB lead.
COIN RECYCLER [IS] BCR [MAX COINS | FLOAT <level>]
This must follow a
USB
keyword, and specifies that a BCR coin recycler system is connected
directly to the PC via a USB lead. The optional parameter causes the Paylink start-up code to
send the appropriate message to set the level for the hoppers.