20
To
Learn a new Access Tag User
press;
<PROGRAM> <21> <ENTER> <1-100> <ENTER>
1-100 is User number 1-100. When in learn mode the keypad will beep at
one second intervals for 4 minutes. You must present the access tag to a
proximity reader within this period to learn it into the panel.
To
Delete an existing Access Tag User
press;
<PROGRAM> <22> <ENTER> <1-100> <ENTER>
1-100 is User number 1-100. You must enter the exact Access Tag User
you wish to delete.
To
Find an Existing Access Tag User
press;
<PROGRAM> <23> <ENTER> <0> <ENTER>
When find mode has started the keypad will beep at one second intervals
for 4 minutes. You must present the access tag to a proximity reader
within this period. If the Access Tag/Card code is found in memory the
User number will be displayed at the keypad.
PROGRAMMING/DELETING or FINDING RADIO ZONE CODES
The alarm system can have up to 16 radio detectors (zones) programmed
provided a receiver is fitted to the panel. Any of the 16 zones can be wired
or wireless zones.
The owner can add/remove or find radio zones from
CLIENT
program
mode.
To
Learn a new Radio Detector (zone)
press;
<PROGRAM> <164> <ENTER> <1-16> <ENTER>
1-16 is Zone 1-16. When in learn mode the keypad will beep at one sec-
ond intervals for 30 seconds. You must operate the radio detector within
this period to learn it into the panel.
To
Delete an existing Radio Zone
press;
<PROGRAM> <165> <ENTER> <1-16> <ENTER>
1-16 is Zone 1-16. You must enter the exact Radio Zone number you
wish to delete.
To
Find an Existing Radio Zone
press;
<PROGRAM> <166> <ENTER> <0> <ENTER>
During find mode the keypad will beep at one second intervals for 30 sec-
onds. You must operate the radio detector within this period. If the radio
detector code is found in memory the Zone number will be displayed at the
keypad.