background image

Operating instructions for moisture analysers 
UX 3081 
UX 3081WQ 

 
a&p instruments, Kluckhofer Weg 61, D-32657 Lemgo, Tel.:05232 97780, Fax.: 977820  
E-Mail: [email protected], Internet: www.apinstruments.de 

Seite 18 

Technical data  

Scale

Weight range 

400g

 

Resolution 

0.1 g 

Sample volume  

max. 360 cm³ 

Weighing tray 

240 x 110 mm 

For moisture analysis

Initial weight 

any weight from approx. 5 g, recommended from 10 g 

Heater capacity 

Ceramic heater 2x 250 watts (3081)  

 

2x 400 watts (3081 WQ) 

Automatic shut-off  Automatic drying to a constant weight, using 3 factors for I heaters and Q heaters,  

which can be set separately: 

 

Query start, query interval, weight loss/ query interval  

Temperature 

Ceramic heater adjustable from 40°C to 180 °C (3081)  

 

105°C to 360 °C (3081QW)  

Measuring units 

% moisture 

 

% dry matter  

 

% ATRO moisture   

 

g solid matter/ kg 

Reading accuracy 0.1% readable 

Communication

Data terminal 

V24 RS 232/ USB 

Data output 

 all weight and measuring data meet GLP requirements with a start time, optional variable 
interval printout, date, time, total measuring time etc.  

 
Using 

ULTRA X DataBridge

 software can be transmitted to a PC as a   

  

.xls file in Microsoft Excel,  

 

.PDF file. 

For operating the device

Mains connection   230 V 2%/ + 15 % 
Mains frequency  48-63 Hz 
Power input 

250 watts – 850 watts, depending on the model  

Dimensions 

approx. B 385 x D 275 x H 420 mm  

Weight 

approx. 9 kg/ 15 kg (3081 model) 

Technical data subject to change without notice  

 

ULTRA X moisture analysers are stand-alone units and not suitable for use in continuous production runs. We shall not accept 

any liability for incorrect readings!

Summary of Contents for UX 3081

Page 1: ...measurement time gentle and even drying of samples high reproducibility Automatic or time controlled measurement shut off UX 3081 3081WQ Special device for extra large samples e g in the chipboard ind...

Page 2: ...tenance 17 Changing the print ribbon 5 Communication 18 Consumables 14 Data interface 14 Date and time 10 Display 6 Error description and solution 16 Features 1 ID number 9 Installation site 4 Intende...

Page 3: ...ter Repairs should only be carried out by a qualified technician Please take extra care when using flammable samples You may need to contact the manufacturer for advice Please be careful not to drop a...

Page 4: ...ion site Please check the packaging and device for any damage upon delivery Please retain the original packaging in case you need to return the goods to a p instruments Please only use the original pa...

Page 5: ...on on the back of the device Once the device is switched on the current software version is shown followed by the weight display 1 7 In order to prevent weighing system measuring errors the device sho...

Page 6: ...accessed using the up or down button In this instruction manual it is assumed that the down button follows the menu item sequence The menu is operated using a standard structure UP or DOWN Set parame...

Page 7: ...ngs can be defined here 1 Weight loss in mg a value should be defined here which corresponds to approx 0 1 of the original sample e g original sample 10 g 10 mg When the weight loss the mg weight spec...

Page 8: ...described for radiant heaters Measurement unit During measurement the device optionally displays moisture dry matter TS Example 50 moisture 100 Atro moisture Atro i e moisture related to the dry matt...

Page 9: ...t can be selected separately down up down up down up set set set esc down set esc down esc set down up set esc down set set down esc temp C time mode value weight unit temp C time mode value weight un...

Page 10: ...cales Tray carrier and tray must be on the balance Follow the menu instructions and use a F1 weight to calibrate the scales Tray being used must be empty If the display shows switch the power switch o...

Page 11: ...ed The menu can be locked or unlocked as shown below Press and hold the set button for 5 secs Position Enter 5 digit 5x Under scored pin etc oder Position Enter 5 digit 5x Under scored pin etc If you...

Page 12: ...tomatic 2 automatic 1 Here you can choose between the 9 memory places Then the menu set the temperature the weight loss the query interval and the query start All other parameters and settings are not...

Page 13: ...re that the heater is swung back to its rearmost position 3 Measurement values are displayed for the entire length of timethe heater is positioned above the sample The device should not be moved from...

Page 14: ...nd creates a COM interface as soon as the computer is connected to the moisture analyser If this is not the case the driver must be manually installed in the device manager Special software is require...

Page 15: ...set Menu buzzer Buzzer activated deactivated Menu date time Date Day Month Year Time Hours Minutes Men ID Device ID 9999 Device ID 0000 Menu data output Data output without LF with LF Menu printer Pr...

Page 16: ...tact a p instruments Menu Drying parameters cannot be entered only Menu is locked Unlock menu lock contact the person responsible or a p instruments Menu lock cannot be unlocked 5 digit pin for unlock...

Page 17: ...Check shut off settings Timer settings incorrect Printer No printout Printer is faulty or Contact a p instruments no data transmission Contact a p instruments No linefeed Linefeed button or printer is...

Page 18: ...er adjustable from 40 C to 180 C 3081 105 C to 360 C 3081QW Measuring units moisture dry matter ATRO moisture g solid matter kg Reading accuracy 0 1 readable Communication Data terminal V24 RS 232 USB...

Page 19: ...Tray tongs 10000230 for lifting the tray supplied Mains cable H1000019 Mains connection supplied Calibration weight F1 200 g 10000403 for calibrating the scales Aluminium foil 130 mm x 260 mm H100001...

Page 20: ...rating instructions for moisture analysers UX 3081 UX 3081WQ a p instruments Kluckhofer Weg 61 D 32657 Lemgo Tel 05232 97780 Fax 977820 E Mail info apinstruments de Internet www apinstruments de Seite...

Reviews: