background image

 English 

2

 

Dear Customers 

 

Congratulations on purchasing a state-of-the-art A&D blood pressure 

monitor, one of the most advanced monitors available today. Designed 

for ease of use and accuracy, this monitor will facilitate your daily blood 

pressure regimen.   

We recommend that you read through this manual carefully before 

using the device for the first time. 

The 

Bluetooth® 

word mark and logos are registered trademarks owned by 

Bluetooth SIG, Inc. and any use of such marks by A&D is under license. 

Other trademarks and trade names are those of their respective owners.

 

 

Preliminary Remarks 

 

 

This device conforms to the European Directive 93/42 EEC for Medical 

Products. This is made evident by the 

 mark of conformity.  

 

(0123: The reference number to the involved notified body) 

 

The WML-40AH is approved in accordance to R&TTE directive transmitter 

module marked by 

,

 

manufactured by MITSUMI ELECTRIC CO., 

LTD. to OEM product. 

 

The device complies with part 15 of the FCC rules and contains the FCC 

ID POOWML-C40. 

 

Compliance with Industry Canada.   

IC: 4250A-WMLC40. 

 

The device is a Continua certified, 

Bluetooth®

 wireless technology enabled 

medical device. 

 

The device is designed for use on adults only, not newborns or infants. 

 

Environment for use   

The device is for use in the home healthcare environment. 

 

This device is designed to measure blood pressure and pulse rate of people 

for diagnosis. 

 

Precautions 

 

 

Precision components are used in the construction of this device. Extremes 

in temperature, humidity, direct sunlight, shock or dust should be avoided. 

 

Clean the device and cuff with a dry, soft cloth or a cloth dampened with 

water and a neutral detergent. Never use alcohol, benzene, thinner or other 

harsh chemicals to clean the device or cuff. 

 

Avoid tightly folding the cuff or storing the hose tightly twisted for long 

periods, as such treatment may shorten the life of the components. 

 

The device and cuff are not water resistant. Prevent rain, sweat and water 

from soiling the device and cuff. 

 

Do not replace the batteries during use of the device.   

Summary of Contents for UA-767 Plus

Page 1: ...od Pressure Monitor Model UA 767 BT Ci Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione Bedienungsanleitung Übersetzung 1WMPD4003087 ...

Page 2: ...the Arm Cuff 12 How to Take Accurate Measurements 12 Measurement 12 After Measurement 12 Measurements 13 Normal Measurement 13 Measurement with the Desired Systolic Pressure 14 Notes for Accurate Measurement 14 What is an Irregular Heartbeat 15 Pressure Bar Indicator 15 About Blood Pressure 16 What is Blood Pressure 16 What is Hypertension and How is it Controlled 16 Why Measure Blood Pressure at ...

Page 3: ...he device complies with part 15 of the FCC rules and contains the FCC ID POOWML C40 Compliance with Industry Canada IC 4250A WMLC40 The device is a Continua certified Bluetooth wireless technology enabled medical device The device is designed for use on adults only not newborns or infants Environment for use The device is for use in the home healthcare environment This device is designed to measur...

Page 4: ...sing the device repeatedly If you have had a mastectomy please consult a doctor before using the device Do not let children use the device by themselves and do not use the device in a place within the reach of infants There are small parts that may cause a choking hazard if swallowed by mistake by infants Wireless communication devices such as home networking devices mobile phones cordless phones ...

Page 5: ...sure Diastolic Pressure Pulse Rate Battery Indicator I H B Symbol Irregular heartbeat symbol Heart Mark Battery Cover 1 5V Batteries LR6 R6P or AA Battery Compartment Display Air Connector Plug Air Socket Arm Cuff DC Jack START Button Air Hose Index Mark Proper Fit Range Artery Position Mark ...

Page 6: ...easurement LOW BATTERY The indicator blinks when battery power is low Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement during the measurement Try the measurement again Remain very still during the measurement The systolic and diastolic values are within 10 mmHg of each other The pressure value did not increase during inflation The cuff is not fa...

Page 7: ...n EC directive medical device label R TTE directive transmitter module label Manufacturer REP EC EU representative Date of manufacture WEEE label Refer to instruction manual booklet SN Serial number Polarity of DC jack IP International protection symbol ...

Page 8: ...w temperatures Generally four new LR6 batteries will last approximately for six months when used twice for measurement each day Remove the batteries if the device is not to be used for a long time The batteries may leak and cause a malfunction Use the specified batteries only The batteries provided with the device are for testing monitor performance and may have a limited life Connecting the Air H...

Page 9: ... result in reduced communication speeds or which may prevent connection In this case switch off the power supply to the device that is not being used or use the monitor in a different location If the monitor does not connect normally when used near a wireless station or broadcast station use the monitor in a different location A D Company Limited cannot accept liability for any damages incurred du...

Page 10: ...the new device to be paired Some applications may allow pairing with only one device Follow the steps below to pair or unpair the monitor with a Bluetooth compatible receiver device Also refer to the manual of the receiver device Please use a pairing wizard if one is provided Pairing procedure 1 Follow the instructions in the manual of the receiver device to switch it to the pairable status When p...

Page 11: ...g environment so be sure to check that the distance is short enough for a connection to be made after measurement is complete Memory In cases when the receiver device cannot receive measurement data the measurement data is temporarily stored in the monitor memory The data stored in the memory is transmitted the next time a connection is successfully made to the receiver device A total of 200 sets ...

Page 12: ...16 cm to 24 cm Small cuff UA 279 Arm size The circumference of the biceps Symbols that are printed on the cuff Symbols Function Meaning Recommended Action Artery position mark Set the mark on the artery of the upper arm or in line with the ring finger on the inside of the arm Index REF Catalog number Proper fit range for the medium cuff It s printed on the medium cuff Over range printed on the med...

Page 13: ...air Rest your arm on the table Do not cross your legs Keep your feet on the floor and straighten your back Relax for about five to ten minutes before measurement Place the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try ...

Page 14: ... If you wish to stop inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measurement is in progress Once the pulse is detected the mark blinks with each pulse beat Note If an appropriate pressure is not obtained the device starts to inflate again automatically 4 When the measurement is complete...

Page 15: ...otional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure varies constantly depending on what you are doing and what you have eaten What you drink can have a very strong and rapid effect on your blood pressure This device bases its measurements on the heartb...

Page 16: ... varies by 25 from the average of all heartbeats during the blood pressure measurement It is important that you be relaxed remain still and do not talk during measurements Note We recommend contacting your physician if you see this symbol frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement Inflation complete Pressurizing Inflation in progress Measur...

Page 17: ...iding stress and with medication under a doctor s supervision To prevent hypertension or keep it under control Do not smoke Exercise regularly Reduce salt and fat intake Have regular physical checkups Maintain proper weight Why Measure Blood Pressure at Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 25 to 30 mmHg higher than t...

Page 18: ...ry power is low LOW BATTERY mark blinks If the batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not applied properly Apply the cuff correctly You moved your arm or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortably and still Place your arm on a table w...

Page 19: ...c measurement Measurement range Pressure 20 280 mmHg Pulse 40 200 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Power supply 4 x 1 5V batteries LR6 R6P or AA or AC adapter TB 233 Not included Number of measurements Approx 450 measurements when AA Alkaline batteries are used with pressure value of 180 mmHg at room temperature of 23 C Classification Internally powered ME equipment Suppli...

Page 20: ...eriodically TB 233C Input 100 240 V Output 6 V 500 mA TB 233BF Input 100 240 V Output 6 V 500 mA TB 233 Input 120 V Output 6 V 500 mA Accessories sold separately Cuff AC adapter Catalog Number Plug TB 233C Type C TB 233BF Type BF TB 233 Type A Note Specifications are subject to change for improvement without prior notice Catalog Number Cuff Size Arm Size UA 281 Large cuff 14 2 to 17 7 36 cm to 45 ...

Page 21: ...don Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 263 5333 Fax 1 408 263 0119 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 ...

Reviews: