![A&D HW-100KGL Instruction Manual Download Page 48](http://html.mh-extra.com/html/aandd/hw-100kgl/hw-100kgl_instruction-manual_446481048.webp)
HW-G Instruction Manual Page 46
HW-G OZIM v1a
Item
Display
Meaning and purpose
Accumulation
When the display becomes a stable value, the scale
accumulates the data automatically. Next accumulation can
occur after the display becomes near-zero.
f8 4
Use: Recording number and mass of articles removed from
the pan. (Put articles on the pan. Press
TARE
switch at each
removal.)
At each finish of full/dribble batch function, the scale
accumulates the data automatically.
f8 5
Use: Packing articles like a powder, it is used for recording
the bag number and total mass.
The printing condition when using option OP-06 for type V.
f9 0
#
No print.
f9 1
Pressing the
switch, the data is output.
Auto-print +
When the display becomes a positive stable value above
f9 2
near-zero, the scale outputs the data automatically. Next
output can be performed after the display becomes near-
zero or negative value.
Print Mode
Auto-print +/-
When the display becomes a stable value outside near-zero,
f9 3
the scale outputs the data automatically. Next output can be
performed after the display becomes near-zero.
f9 4
At each finish of full/dribble batch function, the data is output.
f9 5
When the accumulation function is used, the data is output.
The details of the full/dribble batch function (
B$'
)
f10 0
# Reaching final value and pressing the
F
switch, the current
process is finished.
f10 1
Reaching final value and displaying the stability mark, the
current process is finished automatically.
f10 2
Pressing the
SET
switch, the scale automatically tares and
starts the full/dribble batch process. Reaching final value and
pressing the
F
switch, the current process is finished.
Full/Dribble
f10 3
Pressing the
SET
switch, the scale automatically tares and
Batch
starts the full/dribble batch process. Reaching final value and
sub-function
displaying the stability mark, the current process is finished.
Address for RS-422 / RS-485 for option OP-04
f11 00
# Use This address can be set from 01 to 99. Allows a
Address
to
computer to control a scale with the assigned address.
f11 99
(RS-232C should be set to “00”.)
?