![A&D HW-100KGL Instruction Manual Download Page 34](http://html.mh-extra.com/html/aandd/hw-100kgl/hw-100kgl_instruction-manual_446481034.webp)
HW-G Instruction Manual Page 32
HW-G OZIM v1a
12 Full/Dribble Batch Function
This function changes the scale to a filling machine which sub-divides a bulk product like
grain into loads of predetermined and virtually constant mass.
It is necessary to set the parameter of the “comparator function (
f6 9
)”, “ full/dribble
batch sub-function (
f10 0
~
f10 3
)” in the function table, final value (HI), preliminary
value (OK) and zero band (LO) in advance to use this function.
It is necessary to install option OP-03 or OP-04, if you use the relay output of the full/
dribble batch function.
In the example of a filling machine with a scale and hopper, the performance and
processing of the system are assumed to be as follows:
Zero Band
Preliminary value Final value
indicator/
indicator/
indicator/
LO relay output OK relay output
HI relay output
Gross < Zero band
(Zero detection level)
ON/Make
OFF/Break
OFF/Break
Net < Final - Preliminary
OFF/Break
ON/Make
ON/Make
Final - Preliminary < Net < Final
OFF/Break
OFF/Break
ON/Make
Final < Net
OFF/Break
OFF/Break
OFF/Break