41
12. OP-02 BATTERY
Using OP-02 SLA Battery
The scale can operate with by an SLA (Sealed Lead Acid) battery that will be
commercially available.
The scale (with no other options) can be operated for around 80 hours by fully
charged battery.
The battery will take about 15 hours to be fully charged.
The battery life will vary depending on how the scale is used, ambient temperature
and so on.
1. Disconnect the AC adapter from the scale.
2. Loosen the two M3 screws and remove the battery cover.
3. Connect the wires in the battery box to the battery.
Be sure to connect RED wire to positive (+ / RED) terminal and BLACK wire to
negative (- / BLACK) terminal. Or there is a risk of explosion.
4. Place the battery into the box and attach the battery cover using the screws
removed in the step 2 above.
5. Press the ON/OFF key and check if the scale works normally.
Use a Yuasa Battery NP4-6 (6V, 4Ah).
Use only the AC adapter that is provided with the HC-
i
scale.
There will be risk of explosion if battery is connected
improperly or replaced with by an incorrect type.
Dispose of the used battery according to the local laws and
regulations.
M3 screws
Battery NP4-6
“+” electrode (RED)
“-” electrode (BLACK)
Battery Cover
Summary of Contents for HC-15Ki
Page 1: ...Counting Scale HC 30Ki HC 15Ki HC 6Ki HC 3Ki WM PD4001164 ...
Page 58: ...56 World map ...
Page 59: ... blank page ...
Page 60: ......